Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study - 08/12/15

Doi : 10.1016/j.otsr.2015.09.031 
N. Tardy , A. Maqdes, P. Boisrenoult, P. Beaufils, P. Oger
 Service d’orthopédie-traumatologie, centre hospitalier Versailles – André-Mignot, 177, rue de Versailles, 78150 Le Chesnay, France 

Corresponding author. Tel.: +33 6 87 55 21 19; fax: +33 1 39 63 87 38.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Theoretically, the properties of second-generation metal-on-metal (MoM) bearings are better for wear, osteolysis and longevity. However, follow-up studies of more than 10 years are rare, in particular with hybrid fixation (cemented stainless steel stems and cementless cup), therefore we evaluated the results of this combination after a mean follow-up of 12.8 years: (1) to analyze the survival rate, (2) to compare it with the survival rate in the same series after 6.4 years (95.8% cup, 94.8% stem), (3) to evaluate clinical and radiographic outcome and (4) to analyze these failures.

Hypothesis

The number of revisions would increase after 10 years.

Materials and methods

We evaluated 106 total hip arthroplasties (THA) (Cedior™ press-fit cup with cemented Acora™ (n=50) and Exafit™ (n=56) stems and 28mm Metasul™ bearings performed between January 1999 and December 2002. The survival rate was calculated by the Kaplan-Meier method. The clinical assessment included the Postel Merle d’Aubigné (PMA) and Oxford scores. The radiographic assessment evaluated radiolucencies and osteolysis on standard X-rays. A histological analysis was only performed during revision THA.

Results

After a mean 12.8 years of follow-up (10–16), 53 THA were reviewed in 48 patients. Thirteen THA revisions (14%) were performed including 11 aseptic revisions (5 stem fractures, 2 cases of impingement and 3 loosenings [1 bipolar and 3 cups] and one case of osteolysis). Overall survival, taking into account revision for aseptic loosening, was 87.6% (CI 95%=77.3 to 99.3%). The mean PMA and Oxford scores at the final follow-up were 17.6±0.8 points (16–18) and 16.5±5.2 points (12–38) respectively. The radiological follow-up mainly identified radiolucencies around the stem in Gruen zones 1 and 7 (17 and 21% respectively).

Discussion

The survival rate of hybrid MoM THA in this series decreased after 10 years and is lower than studies evaluating cementless THA with the 28-mm Metasul™ bearings (90.9 to 100% survival). Although the clinical results are satisfactory, survival is lower. However, the role of MoM bearings is relative in these failures, in particular because trunnionoses (stainless steel stem with 28-mm head), impingement and especially 5-stem fractures were the main causes of failure.

Level of evidence

IV: retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasties, Metal-on-metal bearings


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 8

P. 929-936 - décembre 2015 Retour au numéro
Article précédent Article précédent
  • Can cemented dual-mobility cups be used without a reinforcement device in cases of mild acetabular bone stock alteration in total hip arthroplasty?
  • T.X. Haen, G. Lonjon, E. Vandenbussche
| Article suivant Article suivant
  • Poor reproducibility of the MRI measurement of distal femoral torsion
  • M. Ollivier, C. Stelzlen, P. Boisrenoult, N. Pujol, P. Beaufils

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.