Background

The contralateral femur is often used as reference for reconstruction in unilateral hip joint pathology. The objective of this study was to quantify the side-to-side variation in proximal femur. We hypothesized that significant side-to-side differences exist between left and right femur with implications for preoperative planning and leg length discrepancy following hip arthroplasty.

Materials and methods

CT-based 3D femoral models were reconstructed for 122 paired femurs in 61 young healthy subjects (46.9±6.8 years) with no history of hip pathology. Side-to-side differences of several femoral morphologic parameters, including femoral head diameter, femoral anteversion, horizontal offset and femoral head center location, were compared and correlated with demographic factors using multiple linear regression.

Results

Significant side-to-side differences (P<0.01) were found in femoral anteversion (4.3±3.8°; range: 0.2° to 17.3°), horizontal offset (2.5±2.1mm; range: 0.1 to 10.3mm), and femoral head center location (7.1±3.8mm; range: 0.5 to 19.4mm). The difference in femoral anteversion was strongly correlated with the difference in neck diameter (R2=0.79), whereas the difference in horizontal femoral offset was highly correlated with the head diameter difference (R2=0.72). Femoral head center difference was correlated with the femoral anteversion, horizontal offset and neck-shaft-angle difference (R2=0.82).

Discussion

Relying on the anatomic landmarks of the contralateral femur during hip arthroplasty may not necessarily result in restoration of native anatomy and leg-length. Knowledge of the baseline side-to-side asymmetry could provide a range of error that would be tolerable following hip reconstruction.

Level of evidence

Level IV.

Type of study

Retrospective observational study.

Le texte complet de cet article est disponible en PDF.

Keywords : Proximal femur, Asymmetry, Total hip arthroplasty, Offset, Anteversion, Hip joint center, Geommetric morphometrics


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 1

P. 91-97 - février 2016 Retour au numéro
Article précédent Article précédent
  • Arthroscopy for hip septic arthritis in children
  • I. Sanpera, D. Raluy-Collado, J. Sanpera-Iglesias
| Article suivant Article suivant
  • Kinematic TKA using navigation: Surgical technique and initial results
  • J.R.B. Hutt, M.-A. LeBlanc, V. Massé, M. Lavigne, P.-A. Vendittoli

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.