S'abonner

Percutaneous transgluteal drainage of pelvic abscesses in interventional radiology: A safe alternative to surgery - 25/02/16

Doi : 10.1016/j.jviscsurg.2015.10.006 
B. Robert a, , C. Chivot a, L. Rebibo b, C. Sabbagh b, J.-M. Regimbeau b, T. Yzet a
a University of Picardy, Amiens North Hospital, Department of Digestive and Interventional Radiology, 80000 Amiens, France 
b University of Picardy, Amiens North Hospital, Department of General and Digestive Surgery, 80000 Amiens, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Aim

Interventional radiology plays an important role in the management of deep pelvic abscesses. Percutaneous drainage is currently considered as the first-line alternative to surgery. A transgluteal computed tomography (CT)-guided approach allows to access to deep infected collections avoiding many anatomical obstacles (vessels, nerves, bowel, bladder). The objective of this study was to assess the safety and efficacy of a transgluteal approach by reviewing our clinical experience.

Materials and method

We reviewed medical records of patients having undergone percutaneous CT-guided transgluteal drainage for deep pelvic abscesses. We focused on the duration of catheter drainage, the complications related to the procedures and the rate of complete resolution.

Results

Between 2005 and 2013, 39patients (27women and 12men; mean age: 52.5) underwent transgluteal approach CT-guided percutaneous drainage of pelvis abscesses in our department. The origins of abscesses were postoperative complications in 34patients (87.2%) and infectious intra-abdominal disease in 5patients (12.8%). The mean duration of drainage was 8.3days (range: 3–33). Laboratory cultures were positive in 35patients (89.7%) and Escherichia coli was present in 71.4% of the positive samples. No major complication was observed. Drainage was successful in 38patients (97.4%). A transpiriformis approach was more significantly associated with intra-procedural pain (P=0.003).

Conclusion

Percutaneous CT-guided drainage with a transgluteal approach is a safe, well-tolerated and effective alternative to surgery for deep pelvic abscesses. This approach should be considered as the first-line intention for the treatment of deep pelvic abscesses.

Le texte complet de cet article est disponible en PDF.

Keywords : Transgluteal drainage, Pelvic abscess, Computed tomography, MEOPA, Interventional radiology


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 153 - N° 1

P. 3-7 - février 2016 Retour au numéro
Article précédent Article précédent
  • A Journal of Visceral Surgery with international standing that enhances the recognition of authors, clearly states all links of interest and is plagiarism-free—we owed you this much
  • M. Pocard
| Article suivant Article suivant
  • Falciform ligament flap for the protection of the gastroduodenal artery stump after pancreaticoduodenectomy: A single center experience
  • S. Ray, S. Sanyal, S. Ghatak, P.K. Sonar, S. Das, S. Khamrui, G. Chattopadhyay

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.