S'abonner

Evaluation of tumor response to intra-arterial chemoembolization of hepatocellular carcinoma: Comparison of contrast-enhanced ultrasound with multiphase computed tomography - 04/03/17

Doi : 10.1016/j.diii.2016.09.002 
S.B. Paul a, , E. Dhamija a, S.R. Gamanagatti a, V. Sreenivas b, D.P. Yadav c, S. Jain c,  Shalimar a, S.K. Acharya c
a Department of Radiodiagnosis, All India Institute of Medical Sciences (AIIMS), New Delhi 110029, India 
b Department of Biostatistics, All India Institute of Medical Sciences (AIIMS), New Delhi 110029, India 
c Department of Gastroenterology, All India Institute of Medical Sciences (AIIMS), New Delhi 110029, India 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

To compare the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) with that of multiphase computed tomography (CT) in the evaluation of tumor response to transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC).

Material and methods

Fifty patients (41 men, 9 women; mean age, 53 years±12.5 [SD]) with a total of 70 HCCs (mean size, 5cm±3 [SD]) were evaluated. Post-TACE therapeutic assessment of HCC was done at 4 weeks. Patients with TACE done earlier and reporting with suspicion for recurrence were also included. Patients with hepatic masses seen on ultrasound were enrolled and subjected to CEUS, multiphase CT and magnetic resonance imaging (MRI). Hyperenhancing area at the tumor site on arterial phase of CEUS/multiphase CT/MRI was termed as residual disease (RD), the patterns of which were described on CEUS. Diagnostic accuracies of CEUS and MPCT were compared to that of MRI that was used as the reference standard.

Results

CEUS detected RD in 43/70 HCCs (61%). RD had a heterogeneous pattern in 22/43 HCCs (51%). Sensitivities of CEUS and multiphase CT were 94% (34/36; 95% CI: 81–99%) and 50% (18/36; 95% CI: 33–67%) respectively. Significant difference in sensitivity was found between CEUS and multiphase CT (P=0.0001). CEUS and multiphase CT had 100% specificity (95% CI: 83–100%).

Conclusion

CEUS is a useful technique for detecting RD in HCC after TACE. For long term surveillance, CEUS should be complemented with multiphase CT/MRI for a comprehensive evaluation.

Le texte complet de cet article est disponible en PDF.

Keywords : Contrast-enhanced ultrasound, Multiphase computed tomography (CT), Hepatocellular carcinoma, Trans-arterial chemoembolization, Comparative studies


Plan


© 2016  Éditions françaises de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 3

P. 253-260 - mars 2017 Retour au numéro
Article précédent Article précédent
  • Subchondral linear hyperintensity of the femoral head: MR imaging findings and associations with femoro-acetabular joint pathology
  • P.A. Gondim Teixeira, K.-M. Savi de Tovi, W. Abou Arab, A. Raymond, M. Louis, K. Polet Lefebvre, A. Blum
| Article suivant Article suivant
  • Preoperative grading of supratentorial gliomas using high or standard b-value diffusion-weighted MR imaging at 3T
  • M.M. Cihangiroglu, E. Ozturk-Isik, Z. Firat, O. Kilickesmez, A.M. Ulug, U. Ture

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.