S'abonner

Évaluation de la pertinence des demandes d’anticorps anticytoplasme des polynucléaires neutrophiles : étude rétrospective menée au sein du centre hospitalier universitaire de Bordeaux - 08/07/17

Relevance assessment of requests for antineutrophil cytoplasmic antibodies detection: Retrospective study led in Bordeaux Hospital, France

Doi : 10.1016/j.revmed.2017.06.003 
P. Biscay a, , M. Ralazamahaleo b, E. Lazaro a, c, C. Richez c, d, J. Seneschal c, e, C. Rigothier f, g, h, C. Contin-Bordes b, c, 1, P. Duffau a, c, 1
a Service de médecine interne, hôpital de Bordeaux, hôpital Saint-André, 1, rue Jean-Burguet, 33000 Bordeaux, France 
b Laboratoire d’immunologie et immunogénétique, hôpital de Bordeaux, 33000 Bordeaux, France 
c CNRS-UMR5164 immuno ConcEpT, université de Bordeaux, 33000 Bordeaux, France 
d Service de rhumatologie, hôpital de Bordeaux, 33000 Bordeaux, France 
e Service de dermatologie, hôpital de Bordeaux, 33000 Bordeaux, France 
f Service de néphrologie et transplantation rénale, hôpital de Bordeaux, 33000 Bordeaux, France 
g Université de Bordeaux, bio-ingénierie tissulaire, U1026, 33000 Bordeaux, France 
h Inserm, Bio-ingénierie tissulaire, U1026, 33000 Bordeaux, France 

Auteur correspondant.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 08 July 2017
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Introduction

En 2013, 5943 demandes d’anticorps anticytoplasme des polynucléaires neutrophiles (ANCA) étaient réalisées au CHU de Bordeaux. Ce chiffre paraissait disproportionné au regard de la prévalence des vascularites associées aux ANCA (VAA). Notre objectif était d’évaluer la pertinence de ces prescriptions.

Méthodes

Les demandes d’ANCA de l’année 2013 étaient recueillies, ainsi que leurs résultats. Un échantillon de 501 demandes était secondairement constitué aléatoirement. La pertinence des demandes était évaluée rétrospectivement de manière indépendante par deux opérateurs. Des stratégies d’information visant à diminuer le nombre de prescriptions et à améliorer leur pertinence étaient ensuite évaluées durant l’année 2014.

Résultats

Sur 5943 demandes d’ANCA, seules 17,8 % aboutissaient à un résultat positif en immunofluorescence indirecte (dont 10,6 % à des taux supérieurs au 1/50). En Luminex®, 9,7 % des recherches d’anticorps anti-MPO ou PR3 étaient positives. Au sein d’un échantillon de 501 prescriptions d’ANCA, seulement 28,7 % des demandes étaient pertinentes. Un pourcentage de 40,2 d’entre elles n’étaient justifiées par aucune atteinte viscérale classique des vascularites associées aux ANCA. Exactement 15,9 des demandes étaient réalisées lors de bilans auto-immuns systématiques. Aucune de ces demandes n’aboutissait au diagnostic de VAA. La mise en place conjointe de mesures d’information et d’un questionnaire de justification des demandes d’ANCA permettait une diminution de 19 % du nombre de demandes d’ANCA en 2014, avec une diminution du pourcentage de demandes non justifiées par une atteinte viscérale classique de VAA (de 40,2 % à 17,1 %). Une économie de 46 865 € était ainsi réalisée.

Conclusion

La grande majorité des demandes d’ANCA au CHU de Bordeaux n’était pas considérée comme pertinente et n’aboutissait pas au diagnostic de VAA. Des mesures d’information simples permettaient une amélioration partielle de la pertinence de ces prescriptions.

Le texte complet de cet article est disponible en PDF.

Abstract

Introduction

During year 2013, 5943 tests for antineutrophil cytoplasmic antibodies (ANCA) detection were performed in Bordeaux hospital, France. This seemed disproportionate, with regard to the low prevalence of ANCA-associated vasculitis (AAV). Our purpose was to evaluate the relevance of these requests.

Methods

Requests for detection of ANCA during 2013 were recorded, with their results. A sample of 501 requests was secondarily established. Relevance of requests was assessed independently by two reviewers. During year 2014, we developed strategies of information, in order to reduce the number of requests and increase their relevance.

Results

Only 17.8 % of the 5943 requests for detection of ANCA resulted in a positive test using indirect immunofluorescence (including 10.6 % of the requests with titles above 1/50). Using Luminex©, 9.7 % of the test of detection against antimyeloperoxidase or antiproteinase 3 antibodies were positive. Within the sample of 501 patients, only 28.7 % of the requests were relevant. A percentage of 40.2 of them weren’t justified by a clinical affection typically associated with AAV. Exactly 15.9 of the requests were performed during systematic autoimmune screening. None of these requests could lead to the diagnosis of AAV. Combination of information procedures and use of a request form enabled a 19 % decrease of the number of requests. The percentage of requests without clinical justification also reduced from 40.2 % to 17.1 %. The reduction of the number of requests led to a 46,865 € saving.

Conclusion

The majority of the requests for detection of ANCA was not relevant and could not lead to the diagnosis of AAV. Simple solutions enabled a partial but significant improvement of their relevance.

Le texte complet de cet article est disponible en PDF.

Mots clés : Techniques et procédures diagnostiques, Anticorps anticytoplasmes des polynucléaires neutrophiles, Vascularite

Keywords : Diagnostic techniques and procedures, Antibodies, antineutrophil cytoplasmic, Vasculitis


Plan


© 2017  Société Nationale Française de Médecine Interne (SNFMI). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.