Facteurs de risque de défaut de fixation d’un implant acétabulaire press-fit dans l’arthroplatie totale de hanche - 17/07/17

Risk factors for unsuccessful acetabular press-fit fixation at primary total hip arthroplasty

Doi : 10.1016/j.rcot.2017.06.016 
U. Brulc, V. Antolič, B. Mavčič
 University Medical Centre Ljubljana and Faculty of Medicine, Department of Orthopaedic Surgery, Zaloška cesta 9, 1000 Ljubljana, Slovénie 

Auteur correspondant.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Monday 17 July 2017
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Surgeon at primary total hip arthroplasty, sometimes cannot achieve sufficient cementless acetabular press-fit fixation and must resort to other fixation methods. Despite a predominant use of cementless cups, this issue is not fully clarified, therefore we performed a large retrospective study to: (1) identify risk factors related to patient or implant or surgeon for unsuccessful intraoperative press-fit, (2) check for correlation between surgeons’ volume of operated cases and the press-fit success rate.

Hypothesis

Unsuccessful intra-operative press-fit more often occurs in older female patients, particular implants, due to learning curve and low-volume surgeons.

Materials and methods

Retrospective observational cohort of prospectively collected intra-operative data (2009–2016) included all primary total hip arthroplasty patients with implant brands that offered acetabular press-fit fixation only. Press-fit was considered successful if acetabulum was of the same implant brand as the femoral component without additional screws or cement. Logistic regression models for unsuccessful acetabular press-fit, included patients’ gender/age/operated side, implant, surgeon approach (posterior n=1206, direct-lateral n=871) and surgery date (i.e. learning curve).

Results

In 2077 patients (mean 65.5years, 1,093 females, 1,163 right hips) were implanted three different implant brands (973 ABG-II™-Stryker, 646 EcoFit™Implantcast, 458 Procotyl™L-Wright) by eight surgeons. Their unsuccessful press-fit fixation rates ranged from 3.5 % to 23.7 %. Older age (odds ratio 1.01 [95 % CI 0.99–1.02]), female gender (2.87 [95 % CI 2.11–3.91]), right side (1.44 [95 % CI 1.08–1.92]), surgery date (0.90 [95 % CI 1.08–1.92]) and particular implants were significant risk factors only in three surgeons with less successful surgical technique (higher rates of unsuccessful press-fit with Procotyl™-L and EcoFit™ [P=0.01]). Direct-lateral hip approach had a lower rate of unsuccessful press-fit than posterior hip approach (P<0.01) but there was no correlation between surgeons’ volume and rate of successful press-fit (Spearman's rho=0.10, P=0.82). Subcohort of 961 patients with 5–7years, follow-up indicated higher early/late cup revision rates with unsuccessful press-fit.

Discussion

Success of press-fit fixation depends entirely on the surgeon and surgical approach. With proper operative technique, the unsuccessful press-fit fixation rate should be below 5 % and the impact of patients’ characteristics or implants on press-fit fixation is then insignificant. Findings of huge variability in operative technique between surgeons of the presented study emphasize the need for surgeon-specific data stratification in arthroplasty studies and indicate the possibility of false attribution of clinically observed phenomena to patient-related factors in pooled data of large centres or hip arthroplasty registers.

Level of evidence

Level III, retrospective observational case control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Press fit fixation, Risk factors



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.