S'abonner

Mechanical alignment technique for TKA: Are there intrinsic technical limitations? - 07/11/17

Doi : 10.1016/j.otsr.2017.06.017 
C. Rivière a, , F. Iranpour a, E. Auvinet a, A. Aframian a, K. Asare a, S. Harris a, J. Cobb a, S. Parratte b
a The MSK Lab, Charing Cross Camus, Imperial College London, Laboratory Block, W6 8RP London, United Kingdom 
b Service de chirurgieorthopédique, hôpital Sainte-Marguerite, université Aix-Marseille, 20, avenue Viton, 13009 Marseille, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Mechanically aligned (MA) total knee arthroplasty (TKA) is affected by disappointing functional outcomes in spite of the recent improvements in surgical precision and implant designs. This might suggest the existence of intrinsic technical limitations. Our study aims to compare the prosthetic and native trochlear articular surfaces and to estimate the extent of collateral ligament imbalance, which is technically uncorrectable by collateral ligament release when TKA implants are mechanically aligned.

Study hypothesis

Conventional MA technique generates a high rate of prosthetic overstuffing of the distal groove, distal lateral trochlear facet and distal lateral femoral condyle (Hypothesis 1), and technically uncorrectable collateral ligament imbalance (hypothesis 2)? Disregarding the distal femoral joint line obliquity (DFJLO) when performing femoral cuts explains distal lateral femoral prosthetic stuffing and uncorrectable imbalance (hypothesis 3)?

Methods

Twenty patients underwent a conventional MA TKA. Pre-operative MRI-based 3D knee models were generated and MA TKA was simulated. Native and prosthetic trochlear articular surfaces were compared using in-house analysis software. Following the automatic determination by the planning software of the size of the extension and flexion gaps, an algorithm was applied to balance the gaps and the frequency and amplitude of technically uncorrectable knee imbalance were estimated.

Results

The conventional MA technique generates a significant slight distal lateral femoral prosthetic overstuffing (mean 0.6mm, 0.8mm, 1.25mm for the most distal lateral facet point, groove, and at the most distal point of lateral femoral condyle, respectively) and a high rate of type 1 and 2 uncorrectable knee imbalance (30% and 40%, respectively). The incidence of distal lateral prosthetic overstuffing (trochlea and condyle) and uncorrectable knee imbalance were strongly to very strongly correlated with the DFJLO (r=0.53 to 0.89).

Conclusion

Conventional MA technique for TKA generates frequent lateral distal femoral prosthetic overstuffing and technically uncorrectable knee imbalance secondary to disregarding the DFJLO when adjusting the femoral component frontal and axial rotations, respectively.

Level of evidence

level 4.

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee replacement, Mechanical alignment, Imbalance, Laxity, Trochlea facet, Retinacula ligament, Stuffing


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 7

P. 1057-1067 - novembre 2017 Retour au numéro
Article précédent Article précédent
  • Alignment options for total knee arthroplasty: A systematic review
  • C. Rivière, F. Iranpour, E. Auvinet, S. Howell, P.-A. Vendittoli, J. Cobb, S. Parratte
| Article suivant Article suivant
  • The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis
  • C. Rivière, F. Iranpour, S. Harris, E. Auvinet, A. Aframian, P. Chabrand, J. Cobb

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.