S'abonner

Mise au point et validation d’une méthode de dosage du plomb dans les matrices végétales par spectrométrie d’absorption atomique - 09/01/18

Development and validation of an analytical method for the determination of lead in plant matrices by atomic absorption spectrometry

Doi : 10.1016/j.toxac.2017.12.002 
Nadia Chaouali , Anouar Nouioui, Manel Aouard, Omar Smaoui, Dorra Amira, Abderazzek Hedhili
 Laboratoire de recherche en toxicologie et environnement LR12SP07, centre d’assistance médicale urgente, Montfleury, 1008 Tunis, Tunisie 

Auteur correspondant.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 09 January 2018
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Introduction

Le développement industriel, agricole et urbain s’est accompagné lors des dernières décennies de véritables problèmes sanitaires liés à la pollution de l’environnement. Les sociétés industrielles, grandes productrices et consommatrices de métaux, relarguent dans l’environnement des quantités considérables d’éléments traces métalliques, principalement le plomb.

Objectifs

Le travail est articulé sur deux axes, la mise au point et la validation d’une méthode analytique de dosage du plomb dans les matrices végétales par spectrométrie d’absorption atomique électrothermique (SAA-ET) ainsi que l’application de cette méthode sur des échantillons de plantes recueillis au niveau d’une zone industrielle.

Matériels et méthodes

Trente échantillons de feuilles de laurier rose (Nerium oleander) ont été prélevés à partir d’un site industriel qui héberge plusieurs usines de métallurgie et de fabrication d’accumulateurs électriques pour le dosage du plomb total par spectrométrie d’absorption atomique avec four graphite par la méthode des ajouts dosés.

Résultats

La détermination de la teneur du plomb dans les feuilles de laurier rose a été réalisée par la méthode des ajouts dosés. Les limites de détection et de quantification étaient respectivement 0,08μg/g et 0,26μg/g. La précision ainsi que la reproductibilité de la méthode étaient jugées acceptables puisque les valeurs des coefficients de variation de répétabilité étaient respectivement inférieures à 5 % et à 10 %. La justesse de la méthode était confirmée puisque le taux de recouvrement était compris entre 90 et 110 %. D’autre part, cette étude nous a permis de montrer l’impact de la pollution environnementale sur les plantes puisque nous avons retrouvé des teneurs en plomb total très élevés (22±29,711ppm) par rapport à des échantillons témoins (0,91±0,231ppm). Certaines teneurs ont atteint le seuil de phytotoxicité de 30ppm, tandis que d’autres ont même dépassé le seuil limite de 100mg/kg de matière sèche fixé par l’association française de normalisation (Afnor).

Conclusion

La procédure analytique présentée pour la détermination du plomb total dans les matrices végétales est conforme et nous a permis dans les conditions imposées, d’évaluer la teneur en plomb total dans la matrice végétale. Les résultats de ce travail nous ont permis de constater l’impact réel des usines et du trafic routier sur la pollution environnementale.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

In recent decades, industrial, agricultural and urban development have been accompanied by real health problems linked to environmental pollution. Industrial companies release considerable quantities of trace metals mainly lead into the environment.

Objective

The work is articulated on two axes, the development and validation of an analytical method for the determination of lead in plant matrices by electrothermal atomic absorption spectrometry (SAA-ET) as well as the application of this method on plant samples collected in an industrial area.

Materials and methods

Thirty samples of pink laurel (Nerium oleander) leaves were collected from an industrial site that houses several metallurgy and electrical accumulator manufacturing plants, for the determination of total lead by atomic absorption spectrometry with graphite furnace by the standard addition method.

Results

The limits of detection and quantification were respectively 0.08μg/g and 0.26μg/g. The precision and reproducibility of the method were considered acceptable since the values of the repeatability coefficients of variation were respectively less than 5% and 10%. The accuracy of the method was confirmed since the recovery rate was between 90 and 110%. On the other hand, this study showed the impact of environmental pollution on plants since we found very high levels of total lead (22±29.711ppm) compared to control samples (0.91±0.231ppm). Some levels reached the threshold of phytotoxicity of 30ppm, while others have even exceeded the threshold limit of 100mg/kg of dry matter set by the French association of standardization (Afnor).

Conclusion

The analytical procedure presented for the determination of total lead in vegetable matrices is consistent and allowed us, under the imposed conditions, to evaluate the total lead content in the plants matrix. The results of this work allowed us to see the real impact of factories and road traffic on environmental pollution.

Le texte complet de cet article est disponible en PDF.

Mots clés : Plomb, Plantes, Nerium oleander, Spectrométrie

Keywords : Lead, Plants, Nerium oleander, Spectrometry


Plan


© 2017  Société Française de Toxicologie Analytique. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.