Résultats réfractifs et évaluation de la précision du positionnement des implants toriques à l’aide d’un système d’alignement automatisé - 24/04/18

Refractive outcomes and precision in toric intraocular lens alignment using an automated alignment system

Doi : 10.1016/j.jfo.2017.09.012 
T. Cornut a, b, , D. Touboul a, b, S. Rouglan a, L. Tellouck a, b, J. Tellouck a, b, J.-F. Korobelnik a, b, c, C. Schweitzer a, b, c
a Service d’ophtalmologie, CHU de Bordeaux, 33000 Bordeaux, France 
b ISPED, université Bordeaux, 33000 Bordeaux, France 
c Inserm, Bordeaux Population Health Research Center, team LEHA, UMR 1219, université Bordeaux, 33000 Bordeaux, France 

Auteur correspondant. Service d’ophtalmologie, centre François-Xavier-Michelet, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux cedex, France.Service d’ophtalmologie, centre François-Xavier-Michelet, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux cedex, France.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 24 April 2018
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Objectif

Comparer la précision du positionnement des implants toriques et les résultats réfractifs entre un système peropératoire de marquage digital et un marquage manuel.

Méthodes

Étude prospective, comparative, monocentrique avec inclusion consécutive d’une série de patients présentant une cataracte et un astigmatisme cornéen régulier supérieur à 1 dioptrie. L’astigmatisme cornéen total était mesuré par système placido-dual Scheimpflug (Galilei® G4, Ziemer). Les implants toriques Acrysof® SN6AT (Alcon) étaient utilisés et les patients ont été inclus en 2 groupes de méthodes de marquage de l’œil, le groupe digital (Verion®, Alcon) et le groupe manuel (marqueur pendulaire, AMO). L’erreur moyenne d’alignement, l’acuité visuelle et l’astigmatisme résiduel ont été comparés à 3jours, 1 et 6 mois postopératoires.

Résultats

Au total, 45 yeux de 30 patients (n=25 groupe digital, n=20 groupe manuel) ont été inclus. En préopératoire, l’astigmatisme cornéen total moyen était de 1,71±0,53 dioptries. À un mois, l’erreur d’alignement était significativement plus faible dans le groupe digital que dans le groupe manuel avec une erreur moyenne de 2,6±2,3° et de 6,4±2,8°, respectivement (p=0,009). Cette différence était retrouvée à 6 mois. L’astigmatisme résiduel moyen était de 0,7±0,4 dioptries à 1 mois, sans différence significative entre les deux groupes (p=0,9). Ces données étaient stables à 6 mois. 86 % (n=25) des yeux du groupe digital et 63 % (n=20) du groupe manuel présentaient une erreur d’alignement inférieure ou égale à 5°.

Conclusion

Le marquage digital est associé à un meilleur alignement des implants toriques avec des résultats plus reproductibles qu’avec le marquage manuel.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

To compare precision in toric intraocular lens (TIOL) alignment and refractive outcomes between an intraoperative automated digital marker system and the conventional manual-ink marking.

Materials and methods

Prospective single center study including consecutive patients undergoing uneventful cataract surgery with corneal astigmatism greater than 1 diopter. Total corneal astigmatism was measured using a placido-dual Scheimpflug system (GalileiG4®, Ziemer). Acrysof® SN6AT (Alcon) TIOL's were implanted, and patients were divided into 2 groups, the digital group (Verion®, Alcon) and the ink-marking group (Pendular marker, AMO). Mean error in TIOL axis, visual acuity and residual astigmatism were analyzed at 3 days, one month and 6 months after surgery.

Results

In total, 45 eyes of 30 patients were included (n=25 digital group, n=20 ink-marking group). The mean preoperative total corneal astigmatism was 1.71±0.53 diopters. At one month, there was a significantly lower mean average error in TIOL axis in the digital group compared to the ink-marking group (2.6±2.3° and 6.4±2.8° respectively, P=0.009). At 6months, these results remained statistically significant. Mean residual astigmatism was 0.7±0.4 diopters at one month, without significant difference between the two groups (P=0.9). The rate of misalignment less than or equal to 5° was 86 % (n=25) in the digital group and 63 % (n=20) in the ink-marking group (P=0.05).

Conclusion

Intraoperative digital marker system is associated with better TIOL alignment accuracy and better reproducibility than the manual ink-marking method.

Le texte complet de cet article est disponible en PDF.

Mots clés : Astigmatisme, Implant intraoculaire, Toricité, Marquage digital, Cataracte

Keywords : Astigmatism, Intraocular lens, Toricity, Digital marking, Cataract


Plan


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.