A quantitative and semi-automatic measurement of transverse sinus stenosis improves idiopathic intracranial hypertension diagnostic accuracy - 30/06/18
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder
Abstract |
We propose a new reliable transverse sinus stenosis (TSS) index based on magnetic resonance venography (MRV) for the diagnosis of idiopathic intracranial hypertension (IIH). Our quantitative semi-automatic measurement analysis based on segmentation and cross-sectional TS diameter from 48 IIH patients and controls matched for age and sex, had a good inter-observer agreement (κ=0.729) compared to a visual examination (κ=0.467). A cut-off point≥2 discriminate IIH patients from controls, with a sensitivity and specificity of 100%.
Le texte complet de cet article est disponible en PDF.Keywords : Venous stenosis, Transverse sinus, Magnetic resonance venography, Idiopathic intracranial hypertension
Abbreviations : IIH, MRV, CSF, TS, TSS, VSQS, QSAM, MITSS, BMI, ROC, AUC
Plan
Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?