Shunt fraction in Fontan patients: Insights of cardiopulmonary exercise testing - 14/08/18

Doi : 10.1016/j.acvdsp.2018.06.030 
Olivia Domanski 1, 2, , Ali Houeijeh 1, Marie-Paule Guillaume 1, Jean-Benoît Baudelet 1, Regis Matran 2, David Montaigne 3, 4, François Godart 4
1 CHU de Lille, Department of Pediatric and Congenital Heart Diseases, 59000 Lille, France 
2 CHU de Lille, Department of Respiratory Functional Investigations, 59000 Lille, France 
3 CHU de Lille, Department of Clinical Physiology & Echocardiography, 59000 Lille, France 
4 Inserm UMR1011, University Lille 2, 59045 Lille, France 

Corresponding author.

Résumé

Introduction

Fontan patients can develop veno-venous shunts with time, which are usually closed percutaneously when they reduce oxygen saturation. But the significance of these shunts regarding the type of congenital heart disease or surgical repair and their clinical relevance is not well known.

Objective

The purpose of this study was to evaluate the proportion of Fontan patients presenting veno-venous shunt and to evaluate the impact on aerobic capacity.

Results

Twenty-six Fontan patients (mean age 23±9 years) who underwent cardiopulmonary exercise testing with blood gas measurement between January 2016 and January 2018 were included. Twenty patients had total cavopulmonary connection with extracardiac conduit surgery and 6 had atriopulmonary connection. Mean oxygen saturation at rest was 94.9±2.1%. A resting shunt fraction, defined as PaO2+PaCO2<120mmHg was found in 100% of patients, with a mean of 96±6mmHg. In the group of patients presenting an important shunt fraction (defined as PaO2+PaCO296mmHg), patients reached a lower maximal workload (102±24 versus 121±38 watts, P=0.07 or 58±10 versus 69±15% of predicted value, P=0.04) and had lower maximal oxygen consumption (22±6 versus 27±9mL/kg/min, P=0.06 or 54±9% versus 69±16% of predicted value, P<0.01). There was a small correlation between the importance of shunt fraction and maximal oxygen consumption, r2=0.22.

Conclusion

The importance of shunt fraction in Fontan patients seems correlated to aerobic capacity. Further studies are needed to confirm these results. Whether percutaneous closing of veno-venous shunts in Fontan patients can reduce this shunt fraction and could improve maximal oxygen consumption still remains to be proved.

Le texte complet de cet article est disponible en PDF.

Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 10 - N° 3-4

P. 287 - septembre 2018 Retour au numéro
Article précédent Article précédent
  • Speckle tracking echocardiography in children with Duchenne muscular dystrophy: A multicenter controlled cross-sectional study
  • Pascal Amedro, Marie Vincenti, Grégoire De La Villeon, Kathleen Lavastre, Catherine Barrea, Sophie Guillaumont, Charlene Bredy, Lucie Gamon, Albano C. Meli, Olivier Cazorla, Jeremy Fauconnier, Pierre Meyer, François Rivier, Jerome Adda, Thibault Mura, Alain Lacampagne
| Article suivant Article suivant
  • The effect of beta-blockers therapy on progression of thoracic aortic dilatation in the young Marfan syndrome patients: Difference between subtypes of FBN1 gene mutation
  • Ngoc-Thanh Kim, Julie Plaisancie, Thomas Edouard, Miarisoa Ratsimandresy, Philippe Acar, Yves Dulac

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.