S'abonner

La fixation par vis par voie mini-invasive dans les fractures en T de l’acétabulum est aussi stable que la plaque antérieure : étude biomécanique - 20/09/18

Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures – a biomechanical study

Doi : 10.1016/j.rcot.2018.08.026 
Christopher A. Becker a, Christian Kammerlander a, Adrian C. Kussmaul a, Fabian Dotzauer a, b, Matthias Woiczinski c, Bianka Rubenbauer a, Fabian Sommer a, Christoph Linhart a, Simon Weidert a, Christian Zeckey a, Axel Greiner a,
a Department of General Trauma & Reconstructive Surgery, University Hospital LMU Munich, Marchioninistr 15, 81377 Munich, Allemagne 
b Department of Trauma Surgery, Hospital of Schongau, Marie-Eberth-Straße 6, 86956 Schongau, Allemagne 
c Department of Orthopedics, Physical Medicine and Rehabilitation, University Hospital LMU Munich, Marchioninistr 15, 81377 Munich, Allemagne 

Auteur correspondant.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 20 September 2018
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Introduction

Operative treatments of T-type acetabular fractures are challenging surgical procedures. Open reduction and internal fixation is the standard method for the operative management of these fractures, however this is associated with high blood loss, long hospital stay and longer rehabilitation. Anterior subcutaneous pelvic fixation (internal fixation=INFIX) and retrograde pubic screw fixation have shown promising results in minimally invasive treatment of pelvic ring fractures. For T-type acetabular fractures, however, minimally invasive treatment concepts are still rare. Therefore we performed a mechanical in vitro study to: (1) investigate the potential favorability of minimally invasive treatment options over the already established open anterior locking plate osteosynthesis of acetabular T-fractures regarding biomechanical stability and post-surgical stiffness, (2) explore the biomechanical feasibility of the INFIX, (3) assess its potential ability to reduce the anterior acetabular column.

Hypothesis

A minimally invasive treatment of acetabular T- type fractures is biomechanically equivalent to an open anterior plate osteosynthesis.

Methods

Twenty-four synthetic hemipelvis specimens with a T-type acetabular fracture were divided in four groups. A posterior column screw was placed in every pelvis of every group. The anterior column was fixed with (1) anterior column screw, (2) anterior column screw including INFIX, (3) INFIX alone, (4) 14-hole angular stable locking plate (standard fixation method). Displacement of the anterior column was reduced in group 2+3 using the INFIX. All specimens were cyclically loaded with 200N until a maximum of 600N. Movement/displacement of the fracture fragments were detected with a 3D-ultrasound measuring system. Displacement (mm) and stiffness (N/mm) of the construction were analyzed.

Results

Statistical assessment showed no significant differences between the four fixation types (p>0.05). The 14-whole locking plate (group 4) displayed the overall highest stability with a displacement of 1.3±0.04mm and stiffness of 76.3±2.4N/mm. Anterior screw fixation (group 1) proved to be the minimally invasive fixation method with the least displacement and highest stiffness (1.5±0.2mm, 68.3±6.8N/mm). The combination of an INFIX and an anterior column screw (group 2), showed a mean stiffness of 62.1±6.0N/mm and a mean displacement of 1.7±0.2mm. INFIX only (group 3) presented a displacement of 1.6±0.1mm and a stiffness of 64.5±4.5N/mm.

Discussion

Minimally invasive fixation techniques for T-type acetabular fractures show promising biomechanical stability in non- or slightly displaced fractures. Furthermore, INFIX could be a feasible tool for the reduction of the anterior acetabular column.

Level of evidence

Level III case control prospective experimental study.

Le texte complet de cet article est disponible en PDF.

Keywords : Acetabular fracture, Biomechanical study, T-type-fracture, Minimally invasive fixation



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.