S'abonner

08-76 - MITRAL REGURGITATION REDUCTION BY IMPLANTATION OF THE CORCAP CARDIAC SUPPORT DEVICE IN REFRACTORY HEART FAILURE PATIENTS - 09/04/08

Doi : AMCV-12-2007-100-12-0003-9683-101019-200705617 

Patricia Reant [1],

Louis Labrousse [2],

Stephane Lafitte [2],

Laurent Barandon [2],

Stephanie Brette [2],

Pierre Bordachar [2],

Marc-Alain Billes [2],

Marianne Lafitte [2],

Pierre Dos Santos [2],

Claude Deville [2],

Raymond Roudaut [2]

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Background: Mitral regurgitation dramatically decreases prognosis of patients with refractory heart failure. Cardiac Support Device (CorCap®, Acorn Cardiovascular Inc.) is a new surgical treatment of refractory heart failure which has demonstrated reverse left ventricular (LV) remodeling.

Objective: To evaluate the effects of passive containment surgery on the mitral regurgitation.

Methods: From 2002 to 2006, twenty one patients (mean 54.2 ± 8.5 years, range 30 to 69 years, 6 women) were operated on for refractory heart failure with the Corcap® device without associated procedure. Echocardiographic evaluation was performed before surgery, at 3 months, 6 months and 12 months. LV end-diastolic volume, LV end-systolic volume, LV ejection fraction, mitral valve regurgitation (quantified according to the proximal isovelocity surface area method by measuring the effective regurgitant orifice area (EROA)), mitral valvular tenting area, mitral coaptation distance, mitral annulus diameter and systolic sphericity index were measured. Percentage change in EROA and tenting area at 12 months were compared with the percentage change in LV end-diastolic and end-systolic volumes.

Results: Two (9,5%) patients died during the first months after surgery and were excluded of the analysis. For the 19 resting patients, at 12 months, compared to before surgery, LV end-diastolic volume was decreased from 211 ± 52ml to 165 ± 49ml (p < 0.01) (-22%), LV end-systolic volume was decreased from 160 ± 44ml to 117 ± 46ml (p < 0.01) (-26%), LV ejection fraction was increased from 23.6 ± 4% to 31.1 ± 8% (p < 0.01) and mitral regurgitation grade was reduced from mean 1.81 ± 0.87 to 1.16 ± 0.83 (p < 0.01) (-35%) and in 13 (68%) over 19 patients. EROA was reduced from 18.0 ± 9.5 mm2 to 8.4 ± 5.8mm2 (p < 0.01) (-50%). The percentage of change in EROA was well correlated to the percentage of decrease in LV end-diastolic volume (y = 0.35x + 0.03, r = 0.67, p < 0.05) and to the percentage of end-systolic volume (y = 0.39x + 0.06, r = 0.68, p < 0.05).

Concomitantly, the tenting area was decreased from 3.32 ± 0.82cm2 to 2.50 ± 0.89cm2 (p < 0.01) (-25%), the coaptation distance from 15.4 ± 3.3 mm to 11.2 ± 2.6 mm (p < 0.01) (-28%), the mitral annulus diameter from 41.1 ± 4.4 mm 37.6 ± 3.7 mm (p < 0.01) (-8.5%), and the sphericity index from 0.73 ± 0.11 to 0.66 ± 0.10 (p < 0.01) (-9.5%). Significant correlations were equally observed between reduction of tenting area and LV volumes.

These modifications were associated with an improvement of functional capacity (NYHA class, six-minute walking distance and quality of life score).

Conclusions: In this study, the Corcap® procedure allowed improvement of cardiac dimensions associated with a significant reduction of mitral regurgitation in patients with severe refractory heart failure. The positive effect on mitral regurgitation was related to the cardiac reverse remodeling.


Plan



© 2007 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 12

P. 1092-1093 - décembre 2007 Retour au numéro
Article précédent Article précédent
  • 08-75 - LONGITUDINAL LEFT VENTRICULAR DYSFUNCTION PRECEDES RADIAL DYSFUNCTION IN THE TIME COURSE OF SYSTOLIC HEART FAILURE: A VECTOR VELOCITY IMAGING STUDY
  • Rachid Elbelghiti, Stephane Lafitte, Patricia Reant, Hasna Belghiti, Stephanie Brette, Marianne Lafitte, Pierre Dos Santos, Raymond Roudaut
| Article suivant Article suivant
  • 08-77 - NEITHER DOBUTAMINE STRESS ECHOCARDIOGRAPHY NOR GATED-SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IS SUITABLE TO DETECT ASYMPTOMATIC CORONARY STENOSIS IN DIABETIC PATIENTS UNDER DIALYSIS.
  • Yvette BERNARD, Nicolas MENEVEAU, Didier BOUMAL, Sophie BOROT, Emmanuelle RICHARD, Rémi SABBAH, Alfred PENFORNIS

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.