S'abonner

A newly designed locked intramedullary nail for trochanteric hip fractures fixation: Results of the first 100 Trochanteric™ implantations - 25/04/09

Doi : 10.1016/j.otsr.2009.01.002 
F. Loubignac a, , J.-F. Chabas b
a Department of orthopaedics and traumatology “A”, Font-Pré Hospital, Toulon Intercommunity Hospital, 1208, Colonel-Picot avenue, 83056 Toulon cedex France 
b Cosmetic and plastic surgery, Conception Hospital, Public Assistance–Marseille Hospitals, Marseille, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

Internal fixation continues to be the surgical treatment of choice for trochanteric region hip fractures. Intramedullary nailing is the updated version of the Küntscher Y nail and provides stable osteosynthesis of trochanteric hip fractures, classically achieved by closed reduction.

Material and methods

We report on our experience (which started in 2003), using a new fixation device featuring a metaphyseal antegrade nail locked with two cephalic screws and comprising a diaphyseal distal locking. Between April 2003 and September 2006, the first 100 patients who sustained an extracapsular intertrochanteric hip fracture and indicated for internal fixation were prospectively enrolled in this single-center study.

Results

Eighty-six patients (mean age 80.3) were reviewed at 6months (nine had died, three had failure and two were lost to follow-up) and reported a satisfactory functional outcome (mean Merle d’Aubigné score was 16 and mean Harris Hip score was 90). Union was achieved within a mean delay of 3months (median 102 days 1/2) in a good anatomical position (mean medialization was 1.86 – ranging from −16 to 0mm, and mean shortening was 1.72mm – ranging from 0 to 24mm). Functional recovery was satisfactory with a mean Parker score of 7.52. Total operating time was shortened and good fracture stabilization allowed early weight bearing.

Discussion

Classically, such intertrochanteric fractures can be managed either with a dynamic screw-plate type fixation or with an intramedullary nailing device locked through a single cephalic screw and finally, in rare cases, with a hip arthroplasty supplemented with some sort of fixation. Most published clinical studies of screw-plate fixations have generally reported satisfactory results except for unstable fractures associated with a calcar area lesion. Screw-nail fixations featuring a single cephalic screw should be used in these latter fracture patterns. We believe this new implant design will significantly enhance the anatomical result and functional outcome of these fractures; all this is expected to bring about an earlier recovery of patient’s walking ability.

Conclusion

This original intramedullary nailing system provides reliable internal fixation means for intertrochanteric fractures since it combines the advantage of a closed reduction procedure with a more stable biomechanical construct.

Level of evidence: Level IV. Therapeutic prospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Trochanteric fractures, Hip fractures, Internal fixation, Locked nail


Plan


© 2009  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 95 - N° 2

P. 139-144 - avril 2009 Retour au numéro
Article précédent Article précédent
  • Sickle-cell hip necrosis and intraosseous pressure
  • M.M. Mukisi, K. Bashoun, F. Burny
| Article suivant Article suivant
  • Transsupraspinatus arthrotomy through an enlarged transacromial approach for total shoulder replacement
  • D. Goutallier, S. van Driessche, S. Le Mouël, P. Puzzo, S. Zilber

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.