S'abonner

Mini-invasive nail versus DHS to fix pertrochanteric fractures: A case-control study - 09/12/09

Doi : 10.1016/j.otsr.2009.08.007 
E. Foulongne, M. Gilleron, X. Roussignol, E. Lenoble, F. Dujardin
Department of Orthopaedic and Trauma Surgery, Charles Nicolle Hospital, Rouen University Hospital Center, 76031 Rouen cedex, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Background

Fixation devices to treat trochanteric fractures belong to two general categories: dynamic hip screw (DHS) type and intramedullary type implants. In spite of possible pitfalls, both are considered valid options. Comparing a sliding screw-plate system (DHS) along a mini-invasive nailing device (BCM™ nail) with primary insertion of the cephalic screw, sheds light on the debated management of trochanteric fractures.

Hypothesis

Due to its design, the BCM™ nailing system allows a stable internal fixation and promotes enhanced postoperative functional recovery.

Objectives

To test this hypothesis in a comparative prospective case-control study using the DHS screw-plate as a reference.

Materials and methods

Two groups of 30 patients, older than 60 years old, with trochanteric fractures were included in this study. The screw-plates were placed according to the standard method. Regarding the nailing system, the cephalic screw was positioned first, then the nail was inserted through the screw via a mini-invasive approach and locked distally using a bicortical screw. Comparison between the two groups was based on (1) operative data: operating time, intra- and postoperative blood loss; (2) immediate postoperative course: complications, length of hospital stay, delay to sitting in a wheelchair; (3) the postdischarge evolution: weightbearing, readmission to hospital; (4) functional outcomes: recovery and mobility; (5) anatomical outcomes: restitution and bone healing.

Results

The operating time (54±8.8min vs 59±13.8min) and intraoperative (1.37±0.98 vs 1.90±1.43) and at Day 3 (1.25±1.05 vs 1.82±1.5) blood loss (haemoglobin loss), were favourable to the screw-plate subgroup (p<0.05). The delay to sitting in a wheelchair (4.76±1.53d vs 4±1.44d) was favourable to the nail subgroup (p<0.05). There was a higher incidence of secondary displacements in the screw-plate subgroup (3/26 [11.5%] vs 0/25 [0%]) (p<0.05). The screw-plate subgroup demonstrated a poorer healing rate at 3 months (88% vs 100%) (p<0.05). Regarding functional recovery, a lesser decrease in the Parker score was observed in the nail subgroup at 3 postoperative months (2.42±2.3 vs 1.52±1.44) (p<0.05).

Conclusion

This study has shown the benefits of the BCM™ nail in terms of stability. But the potential advantages of this mini-invasive technique were limited by ancillary-related difficulties which need to be rectified. These preliminary results are in favour of a further development of this innovating device.

Level of evidence

Level III. Case-report study.

Le texte complet de cet article est disponible en PDF.

Keywords : Trochanteric fractures, Internal fixation, Intramedullary nailing, Mini-invasive surgery, DHS


Plan


© 2009  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 95 - N° 8

P. 592-598 - décembre 2009 Retour au numéro
Article précédent Article précédent
  • Severe slipped capital femoral epiphysis: The Dunn’s operation
  • M. Lawane, M. Belouadah, G. Lefort
| Article suivant Article suivant
  • Fixed versus mobile bearing unicompartmental knee replacement: A meta-analysis
  • T.O. Smith, C.B. Hing, L. Davies, S.T. Donell

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.