S'abonner

Large diameter head metal-on-metal bearings total hip arthroplasty: Preliminary results - 13/01/10

Doi : 10.1016/j.otsr.2009.09.013 
P. Mertl a, , O. Boughebri b, E. Havet a, P. Triclot c, J.-F. Lardanchet a, A. Gabrion a
a Department of orthopaedics and traumatology, North Hopital, Amiens Teaching Hospital Center, place Victor-Pauchet, 80053 Amiens cedex, France 
b Department of orthopaedics and traumatology, Rouen Teaching Hospital Center, hôpital Charles-Nicolle, 1, rue Germont, 76000 Rouen, France 
c Private Hospital Saint-Grégoire, 6, boulevard de la Boutière, 35768 Saint-Grégoire, France 

Corresponding author. Tel.: +03 22 66 83 10.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 13 January 2010
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

Although the use of the metal-on-metal bearings has been validated over the long term in total hip arthroplasty (THA) for standard 28 and 32mm diameters, and over the medium term in resurfacing procedures, the use of larger metal head size in conventional THA has not yet been extensively reported.

Hypothesis

The large-diameter metal-on-metal head is beneficial in terms of implant stability without altering the result in terms of function and bone fixation compared to the standard 28 and 32mm diameters.

Objective

The objective was to test this hypothesis by assessing the short-term clinical and radiographic results of a metal-on-metal large-diameter heads THA system, using cups from the resurfacing hip concept.

Material and methods

We conducted a retrospective study on a continuous series of 106 uncemented acetabular cups (Durom™) implanted in 102 patients (mean age, 66 years): 93 cases of primary or secondary coxarthrosis, 11 cases of aseptic osteonecrosis, one fracture of the femoral neck, and one case of rheumatoid arthritis of the hip. At 30 months of follow-up, the Harris Hip Score and the Merle d’Aubigné (PMA) score were calculated. The radiological investigation included comparison of the implant head with native head diameters, variations of acetabular center of rotation, inspection for implant migration, and search for a gap or radiolucent line.

Results

The series included two post-traumatic dislocations as well as spontaneously receding tendinitis of the gluteus medius with no further recurrence. The mean Harris Hip Score improved from 49.3 preoperatively to 91.6 at the latest follow-up and the mean PMA score ranged from 12 to 17. The results were excellent for 70 cases, good for 31 cases, fair for three cases, and poor for two cases. In the last five cases, the overall results were undermined by low pain subscore, with no identifiable explanation. Restoration of the original head diameter was verified for 65 hips. No cup migration was observed. Measurement of the acetabular centre of rotation showed a mean lateralization of 1.1mm. Of the 67 immediate postoperative gaps, only two did no disappear at follow-up. Implant head diameter, cup position, and the existence of a gap were not correlated with the clinical results.

Discussion

These results are comparable to 28mm-diameter metal-on-metal heads in uncemented cups but with improved stability but without demonstrable alteration of the quality of the bone fixation. We found no mechanical or medical cause that could explain the five cases of persistent pain leading to fair or poor results. Long-term follow-up will validate these theoretical advantages in terms of wear and implant survival.

Level of evidence

IV. Retrospective series.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Large diameter, Large size head, Metal-on-metal bearings


Plan


© 2009  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.