S'abonner

Do tantalum components provide adequate primary fixation in all acetabular revisions? - 13/04/10

Doi : 10.1016/j.otsr.2009.11.014 
X. Flecher a, , W. Paprosky b, J.-C. Grillo a, J.-M. Aubaniac a, J.-N. Argenson a
a Osteoarthritis Treatment Surgical Center, South Marseille Teaching Hospital Center Sainte-Marguerite Hospital, 270, boulevard Sainte-Marguerite, BP 29, 13274 Marseille, France 
b Department of Orthopedic Surgery, Central Dupage Hospital, 25N Winfield Road, Winfield, IL 60290, United States of America 

Corresponding author. Tel.: +33 4 91 74 50 12; fax: +33 4 91 74 15 91.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 13 April 2010
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

A number of studies have reported favorable results of cementless fixation in acetabular revisions. Nevertheless, the implant bearing on more than 50% of the patient’s bone and good primary stability are required. The objective of this study was to determine whether the use of tantalum implants could provide stable reconstruction for any type of acetabular revision.

Patients and methods

This study investigated 72 hips (71 patients) implanted with tantalum cups, some with augments, and morselized graft material. The mean age was 60 years (range, 34–84 years). There were 30 males and 41 females. The mean weight was 71 kg (range, 52–102 kg), the mean height was 1.68 m (range, 1.52–1.84 m). Twenty-five revisions were bipolar. Six revisions were performed for infected acetabular loosening. The mean follow-up was 4 years (range, 2–6 years).

Results

The mean Merle d’Aubigné score at follow-up was 15.8 points (range, 9–18 points). According to the Paprosky classification of acetabular bone defects, there were 13 type 1 (18%), 14 type 2A (19.5%), 14 type 2B (19.4%), 23 type 3A (31.9%), and eight type 3B (11.2%) acetabular defects, four of which had pelvic discontinuity. Postoperatively, the position of the hip’s center of rotation in relation to Köhler’s teardrop was 22 mm (range, 5–41 mm) vertically (normal, < 25 mm) and 39mm (range, 13–55 mm) horizontally (normal, < 35 mm). The mean acetabular inclination was 40° (range, 20°–63°). The radiographic analysis found no radiolucent line after 1 year and up to the last follow-up. None of the patients required revision for acetabular loosening. Three hips were revised for instability. Two retentive liners and a dual-mobility cup were cemented in the cups that were left in place.

Discussion and conclusion

Given their mechanical properties (coefficient of friction, porosity), tantalum implants provide a stable primary cementless fixation without compromising the center of rotation and without necessarily requiring a structural graft. A single implant range can therefore be used for any type and severity of bone loss and for all types of acetabular reconstruction. Longer follow-up is nevertheless necessary to confirm these encouraging results.

Level of evidence

Level IV, historical series.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Revision, Acetabular loosening, Cementless, Biological fixation, Tantalum, Trabecular metal


Plan


© 2010  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.