S'abonner

Survival analysis of an asymmetric primary total knee replacement: A European multicenter prospective study - 07/10/10

Doi : 10.1016/j.otsr.2010.06.006 
C. Delaunay a, , G. Blatter b, J.-P. Canciani c, D.L. Jones d, P. Laffargue e, H.W. Neumann f, G. Pap f, C. Perka g, M.J. Sutcliff d, H. Zippel g

the European “Natural Knee Group (TM)”

a De l’Yvette Private Hospital, 67, route de Corbeil, 91160 Longjumeau, France 
b Kantonsspital St. Gallen, St. Gallen, Switzerland 
c Saint-Grégoire Private Hospital Center, 35760 Saint-Grégoire, France 
d Edith Cavell Hospital, Cambridgeshire, United Kingdom 
e Robert-Salengro Hospital, Lille University Hospital, 59037 Lille, France 
f Orthopädische Universitäitsklinik Magdeburg, Magdeburg, Germany 
g Charité University Hospital, Berlin, Germany 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 07 October 2010
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Purpose of the study

This multicenter prospective study objective is to provide midterm results and 10-year survival analysis of the original Natural Knee-I System™ as experienced by a group of surgeons performing, within various settings, primary total knee replacement (TKR) in the general population.

Hypothesis

The midterm experience with this TKR system in the hands of independent surgical teams can duplicate the satisfaction level that was already published by the designer’s group itself.

Material and method

Two hundred and sixty-three primary TKR were performed by seven surgical teams (37 surgeons) and prospectively evaluated in four European countries. Mean age of the 263 patients (sex ratio, 2.7 females/1 male) was 69 years (range, 35–92) and diagnosis was primary osteoarthritis in 85%. For the 247 TKR with complete operative data, the approach was subvastus in 59%, posterior cruciate ligament was spared in 78%, patella was resurfaced in 56%, and 79% of reconstructions were totally cement-free. Fixation mode was only depending on the surgeon’s choice.

Results

At 76 months average follow-up (range 24–190 months), modified Hospital for Special Surgery knee mean score improved from 48 points preoperatively to 83 points. Four reoperations and five revision procedures were required for eight knees. Over the 14-year survey period, the overall revision rate burden was 2% and revision rate per 100 observed component/year, 0.32. At 10 years, survivorship (with revision for aseptic loosening as its end-point [two fully cementless knees]) was 98.6%.

Discussion

Both this multicenter study and data drawn from national registers provided outcomes with equivalent level of satisfaction at equivalent follow-up to those reported by the NK-I prosthesis designer. There was no significant difference between revision rates of cemented, hybrid or cementless reconstructions.

Conclusion

In non-designer orthopaedists’ hands, the Natural Knee-I System™, either with cemented or cementless fixation, provided satisfying midterm results as normally expected in primary TKR with such a modern modular prosthesis.

Level of evidence

Level IV. Prospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee replacement, Asymmetric base-plate, Survival analysis


Plan


© 2010  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.