Orthopaedics, Traumatology, plastic and reconstructive surgery and Hand salvage Department, EA 4268 Innovation, Imaging, Engineering and Healthcare policy Division, IFR 133 Inserm, Innovation and Surgical Technique sub-unit, Jean Minjoz Teaching hospital Center, Franche Comté University, Besançon, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

Comminuted fractures of the proximal ulna are severe injuries often associated with bone and ligament injuries of the elbow joint (Monteggia lesion, radial head fractures, dislocation of the elbow). The treatment of these fractures is very demanding and the functional results often fairly mediocre due to associated injuries. Based on a single-center retrospective study, we report the results of the treatment of these fractures fixed using a double-plate technique. The aim was to evaluate the feasibility and reliability of this fixation mode and to compare it with other fractures series using a single plate fixation (in terms of bone union, elbow joint function, and complications stemming from the plates).

Patients and methods

Eighteen patients sustained a comminuted proximal ulna fracture between 2002 and 2006. The fractures were associated in five cases with a Monteggia type lesion, in two cases with elbow dislocation, and in four cases with a Mason 3 radial head fracture. Four patients had an open fracture. These comminuted ulna fractures included nine Mayo Clinic IIIB fractures. Bone fixation was performed with two third-cylinder tubular plates, one plate on each side of the proximal ulna. This allows more versatile solutions for screw insertion. Functional assessment (according to Broberg and Morrey) and radiological evaluation (bone healing) were provided at 6 months and at the longest follow-up by an independent surgeon.

Results

Sixteen of 18 patients achieved bone union. No septic complications occurred and no hardware removal was required on patient request. In 67% of the cases, the Morrey score indicated excellent or good results with a mean score of 82.

Discussion

There are no reports in the literature on the technical point of fixation concerning complex fractures of the ulna. Two plates mean the possibility of twice the number of screw insertions for epiphyseal reconstruction . This fixation remains easy to perform and provides stable anatomic reconstruction of the ulna.

Level of evidence

Level IV. Retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Ulna fracture, Fixation by plate


Plan


© 2010  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 96 - N° 7

P. 734-740 - novembre 2010 Retour au numéro
Article précédent Article précédent
  • Intermediate term functional outcome prediction following full thickness rotator cuff tear reparative or not reparative surgery
  • D. Goutallier, J.-M. Postel, X. Chevalier, J. Beaudreuil, S. Zilber
| Article suivant Article suivant
  • Congenital scoliosis: A frontal plane evaluation of 251 operated patients 14 years old or older at follow-up
  • M.-L. Louis, J.-M. Gennari, A.-D. Loundou, G. Bollini, M. Bergoin, J.-C. Bernard, B. Biot, C. Bonnard, J.-L. Clément, C. Garin, K. Kamoun, G. Kreichati, P. Lascombes, J.-F. Mallet, L. Miladi, J. Sales de Gauzy, V. Topouchian, J.-M. Vital

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.