S'abonner

Laxity measurements using stress radiography to assess anterior cruciate ligament tears - 18/12/10

Doi : 10.1016/j.otsr.2010.08.004 
J. Beldame , S. Bertiaux, X. Roussignol, B. Lefebvre, J.-M. Adam, F. Mouilhade, F. Dujardin
Orthopaedic Surgery and Traumatology Department, Rouen Teaching Medical Center, 1, rue de Germont, 76031 Rouen cedex, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 18 December 2010
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

The clinical diagnosis of the anterior cruciate ligament (ACL) tear is based on demonstrating anterior subluxation of the tibia on the femur. In any of the following perspectives, diagnostic (cutoff value confirming rupture), prognostic (treatment efficacy), and therapeutic (laxity influencing the treatment), this laxity can be measured on stress X-rays.

Working hypothesis

The diagnostic value of dynamic radiographs is low for ACL rupture. Passive Telos® X-rays have better diagnostic value, better radiologic quality, and are easier to carry out than active Franklin-type X-rays.

Material and methods

A cohort of 112 patients (28 females, 84 males; mean age, 33.7 years [range, 18–72 years]) with an indication for knee arthroscopy were studied prospectively. Before undergoing the arthroscopic treatment, two series of images of both knees were taken: one series of passive anterior drawer dynamic X-rays on a Telos® device at 250 N and a series of active anterior drawer dynamic X-rays according to Franklin (contraction of the quadriceps against 7 kg of weight at the ankle). The arthroscopic evaluation of the ACL (reference status) was compared to the anterior laxity measurements (absolute and differential) of each knee compartment (medial, lateral, and average) to determine the diagnostic value of the two radiological tests.

Results

We found 70 patients with an “arthroscopically ruptured ACL”, 32 with an “arthroscopically healthy ACL”, and 10 with a “partial rupture”. The measurement of the anterior drawer values on the dynamic X-rays (active and passive) by two independent observers was reliable and reproducible (ICC>0.80), particularly when using the medial compartment (ICC=0.96) and the differential values eliminating the interobserver measurement error and interindividual laxity variations. In terms of X-ray technique, the active images were more frequently painful and the radiographic result showed less good quality than the Telos images. The anterior drawer values in the “healthy ACL” group were significantly less than in the “ruptured ACL” group for the Telos® images, whether the measurements were absolute or differential. For the Franklin images, this difference was only significant for the absolute values. Used for diagnosis (4-mm differential on the medial compartment), the passive dynamic images had lower diagnostic values (Se=59% and Sp=90%) than the series reported in the literature, which were marked by great heterogeneity.

Conclusion

The measurement of anterior drawer values on Telos® and Franklin dynamic X-rays is a reliable and reproducible measurement, particularly when using the medial compartment and differential measurements. This small series did not demonstrate a diagnostic value for the Franklin images, contrary to the Telos® X-rays. Used for diagnostic purposes, the Telos® images had a low sensitivity; consequently, they should be used preferentially for prognostic or therapeutic purposes.

Level of evidence

Level III, prospective case-control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Anterior knee laxity, Laxity measurement, Anterior cruciate ligament, Dynamic X-rays, Telos®


Plan


© 2010  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.