Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: A 59 cases series with a mean 8 years’ follow-up - 28/01/11

Doi : 10.1016/j.otsr.2010.08.003 
F. Leiber-Wackenheim a, b, , B. Brunschweiler a, M. Ehlinger b, A. Gabrion a, P. Mertl a
a Orthopedics Department, Amiens University Hospital, place Victor-Pauchet, 80054 Amiens, France 
b Orthopedics-Traumatology Department, Hautepierre University Hospital, 1, avenue Molière, 67098 Strasbourg, France 

Corresponding author. Tel.: +33 3 88 12 77 19; fax: +33 3 88 12 77 13.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 28 January 2011
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

Instability is one of the most feared complications following total hip replacement (THR). In France, dual-mobility cups are widely used in acetabular revision for instability; few studies, however, have focused on this type of implant.

Hypothesis

The gain in stability provided by the dual-mobility implant allows the risk of dislocation to decrease by the sole revision of the acetabular component in case of recurrent instability.

Objectives

This hypothesis was tested over medium-term follow-up of a series of cementless dual-mobility cups implanted during isolated acetabular revision for recurrent dislocation.

Patients and methods

A series of THR revision for instability was analyzed retrospectively. Inclusion criteria were: recurrent THR dislocation treated by cementless dual-mobility cup, between 1995 and 2001. Radiological analysis used Imagika™ software. Fifty-nine patients were included; nine died before radioclinical follow-up could be performed; none of the survivors were lost to follow-up. Mean follow-up was 8 years (range, 6–11 years).

Results

There was one early dislocation without recurrence; the dislocation rate was 1.7%. At follow-up, mean PMA score was 16.5 (12–18) and mean Harris score 86.7 (49–99). Radiologically, there was no loosening or migration, but 19% of X-ray views showed less than 1mm wide peri-acetabular radiolucency. With dislocation as censoring criterion, 8-year survivorship was 98% (95% CI: 95–100%).

Discussion

The dislocation rate (1.7%) and clinical results were better than in most series of revision by constrained cup for recurrent dislocation. The high rate of peri-acetabular radiolucency would seem to relate to the external coating of the cup: aluminum oxide in the Novae-1 implant and aluminum oxide/hydroxyapatite in the Novae-E.

Conclusion

The use of dual-mobility cups to treat THR instability gave satisfactory results. We recommend dual-mobility cups with hydroxyapatite surface treatment over a porous metallic substrate, rather than with an aluminum oxide or an aluminum oxide/hydroxyapatite bilayer coating.

Level of evidence

Level IV. Retrospective Study.

Le texte complet de cet article est disponible en PDF.

Keywords : Dislocation, Recurrence, Total hip replacement, Dual-mobility, Revision


Plan


© 2010  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.