S'abonner

Component positioning in primary total hip replacement: A prospective comparative study of two anterolateral approaches, minimally invasive versus gluteus medius hemimyotomy - 10/02/11

Doi : 10.1016/j.otsr.2010.05.013 
F. Mouilhade a, , J. Matsoukis b, P. Oger c, C. Mandereau a, V. Brzakala a, F. Dujardin a
a Academic Department of Orthopedic Surgery and Traumatology, Rouen University Hospital, 1, rue de Germont, 76000 Rouen, France 
b Orthopedic Department, Le Havre Hospital Group, J. Monod Hospital, 29, rue Pierre-Mendès, 76290 Montivilliers, France 
c Orthopedic Department, Mignot Hospital, 177, route de Versailles, 78157 Le Chesnay, France 

Corresponding author. Tel.: +33 0 232880160.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

One factor of implant survivorship in total hip replacement (THR) is the quality of implant choice and positioning. The purported advantages of minimally invasive approaches are faster recovery, shorter hospital stay and less per-operative blood loss. On the other hand, there have been many reports of higher complication rates, and doubts as to the quality of implant positioning.

Hypothesis

The quest to minimize tissue damage is at the cost of THR positioning quality.

Objectives

To assess implant positioning in a prospective comparative continuous multicenter series.

Patients and methods

Between 2008 and 2009, a prospective comparative study was conducted on a continuous series of 141 THRs. Ninety-two were performed in two centers, using a minimally invasive Watson-Jones approach; the other 49, performed in a 3rd center, used an anterolateral approach with anterior hemimyotomy. The surgeons were in all cases experienced in their technique. Short-term follow-up comprised clinical and functional (Postel Merle d’Aubigné (PMA), Harris, SF12, WOMAC) and biological assessment (serum creatine phosphokinase (CPK), myoglobinemia, hematocrit) and analysis of complications and of implant positioning on X-ray and CT-scan.

Results

On the Watson-Jones approach, surgery time was longer; day-1 analgesic administration was lower; PMA, Harris and WOMAC scores were better at 6 weeks; and CPK levels were lower at 24 and 48hours. There were no significant differences on the other clinical and biological criteria. Implant positioning analysis revealed significantly greater combined anteversion and greater variation in acetabular inclination mean with the Watson-Jones approach, but no differences in cup positioning, femoral stem positioning, or limb length discrepancy.

Discussion

The minimally invasive Watson-Jones approach provided faster recovery and less muscular damage. However, implant positioning was less precise in terms of acetabular cup inclination.

Level of evidence

Level III. Prospective, comparative, non-randomized.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Mini-incision, Rottinger, Watson-Jones, Implant positioning


Plan


© 2010  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 1

P. 14-21 - février 2011 Retour au numéro
Article précédent Article précédent
  • Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: A 59 cases series with a mean 8 years’ follow-up
  • F. Leiber-Wackenheim, B. Brunschweiler, M. Ehlinger, A. Gabrion, P. Mertl
| Article suivant Article suivant
  • Non-simultaneous bilateral hip fracture: Epidemiologic study of 241 hip fractures
  • E. Gaumetou, S. Zilber, P. Hernigou

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.