S'abonner

Component impingement in total hip arthroplasty: Frequency and risk factors. A continuous retrival analysis series of 416 cup - 05/03/11

Doi : 10.1016/j.otsr.2010.12.004 
E. Marchetti a, b, N. Krantz a, b, C. Berton a, b, D. Bocquet a, b, N. Fouilleron a, b, H. Migaud a, b, , J. Girard a, b
a Lille–Nord-de-France University, 59000 Lille, France 
b Orthopaedic department, Roger-Salengro Hospital, Lille University Hospital, Place de Verdun, 59037 Lille, France 

Corresponding author. Tel.: +33 0320 446 828; fax: +33 0320 446 607.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 05 March 2011
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

Impingement is a factor of failure in total hip replacement (THR), causing instability and early wear. Its true frequency is not known; cup-retrieval series reported rates varying from 27 to 84%.

Hypothesis

The hypothesis was that a large continuous series of THR cup removals would help determine the frequency of component impingement.

Objectives

The hypothesis was tested on a continuous retrospective series of cups removed in a single center, with a secondary objective of identifying risk factors.

Materiel and methods

Macroscopic examination looked for component impingement signs in 416 cups retrieved by a single operator between 1989 and 2004. Risk factors were investigated by uni- and multivariate analyses in the 311 cases for which there were complete demographic data. In these 311 cases, removal was for aseptic loosening (131 cases), infection (43 cases), instability (56 cases), osteolysis (28 cases) or unexplained pain (48 cases); impingement was explicitly implicated in only five cases (1.6%), always with hard-on-hard bearing components.

Results

Impingement was found in 214 of the 416 cups (51.4%) and was severe (notch>1mm) in 130 (31.3%). In the subpopulation of 311 cups, impingement was found in 184 cases (59.2%) and was severe in 109 (35%). Neither duration of implant use nor cup diameter or frontal orientation emerged as risk factors. On univariate analysis, impingement was more frequently associated with revision for instability, young patient age at THR, global hip range of motion >200° or use of an extended femoral head flange (or of an elevated antidislocation rim liner), and was more severe in case of head/neck ratio<2. On multivariate analysis, only use of an extended head flange (RR 3.2) and revision for instability (RR 4.2) remained as independent risk factors for impingement.

Discussion

Component impingement is frequently observed in cups after removal, but is rarely found as a direct indication for revision, except in case of hard-on-hard friction couples (polyethylene being the most impingement-tolerant material). Systematic use of extended head flanges and elevated antidislocation rims is not to be recommended, especially in case of excessive ROM. A good head/neck ratio should be sought, notably by increasing the head diameter in less impingement-tolerant hard-on-hard friction couples. Although not identified as a risk factor in the present study, implant orientation should be checked; computer-assisted surgery can be useful in this regard, for adaptation to the patient’s individual range-of-motion cone.

Level of evidence

Level IV, retrospective observational study.

Le texte complet de cet article est disponible en PDF.

Keywords : Impingement, Instability, Wear, Hip prosthesis, Dislocation, Retrieval analysis


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.