S'abonner

Maintien tissulaire par friction (« frixation »): qu'attendre du tension-free? - 25/01/07

Doi : 10.1016/j.gyobfe.2006.09.029 
M. Boukerrou a, , E. Lambaudie b, C. Rubod a, H. Yahi a, P. Dubois b, M. Nayama c, M. Cosson a
a Pôle de chirurgie gynécologique, hôpital Jeanne-de-Flandre, centre hospitalier régional universitaire (CHRU) de Lille, 2, avenue Oscar-Lambret, 59037 Lille, France 
b Institut de technologie médicale, pavillon Vancostenobel, centre hospitalier régional universitaire (CHRU) de Lille, 2, avenue Oscar-Lambret, 59037 Lille, France 
c Service de gynécologie-obstétrique, maternité Issaka-Gazobi, BP 623, Niamey, Niger 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 5
Vidéos 0
Autres 0

Résumé

Objectifs

Le principe de mise en place de prothèses sans tension est largement diffusé dans la chirurgie des troubles de la statique pelvienne. Les résultats cliniques semblent favorables. Le but de notre travail est de quantifier les résistances transtissulaires objectives des prothèses avant cicatrisation.

Patientes et méthodes

Nous avons mesuré les résistances tissulaires offertes à cinq types de prothèse par quatre voies d'abord chirurgicales classiques. Nous avons également testé l'incidence de la modification de taille de la bandelette sur la résistance transtissulaire. Ce travail a été réalisé sur cadavres congelés, par traction sur les prothèses juste après implantation. Les mesures sont effectuées à l'aide d'un dynamomètre et les résultats obtenus sont exprimés en newtons.

Résultats

Au niveau du Retzius, la bandelette de TVT® offre une meilleure résistance à la traction par rapport au LIFT®, à l'IVS® et à la bandelette de Prolene® de 1 cm. Nous n'avons noté de différence significative entre les quatre voies d'abord pour un même type de prothèse de 1 cm de large. En revanche, l'augmentation de largeur des bandelettes de Prolene® améliore leur résistance dans les tissus et donc la qualité de leur fixation. Nous avons mis en évidence une meilleure résistance de la voie transligamentaire par rapport à un passage transmusculaire.

Discussion et conclusion

L'augmentation de résistance est liée à l'augmentation de la surface de contact entre la prothèse et les tissus. Cette augmentation de résistance devrait être prise en compte dans les cures de prolapsus dont les contraintes subies sont plus fortes que pour les cures d'incontinence. Les bras de prothèses postérieurs doivent mesurer plus de 1 cm de large et être mis en place au travers du ligament sacro-épineux plutôt qu'au travers des muscles élévateurs. Le type de tricotage des prothèses est important et influe sur la résistance dans les tissus en postopératoire immédiat. Les industriels devraient s'intéresser à la fabrication de matériau prothétique conçu spécifiquement pour la pose sans fixation, sans suture.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

The purpose is to quantify objective tissue resistances before healing of prostheses used in pelvic floor surgery.

Patients and methods

We measured tissue resistances offered to five types of meshes by four classical surgical routes. We also tested the incidence of the modification of the width of meshes on tissue resistance. This study was realized on frozen cadavers, by pull on prostheses just after implantation. Tests are realized with a dynamometer and results obtained in Newton.

Results

In the Retzius space, TVT® offers a better resistance than IVS® or LIFT® meshes. We did not bring to the fore a significant difference between four routes for 1 cm wide prosthesis. The increase of width of Prolene® meshes improves their resistance in tissues and thus quality of their fixation. We underscore a better resistance of the trans sacrospinous route with regard to the trans muscular one.

Discussion and conclusion

The increase of resistance is bound to the increase of the contact area between the prosthesis and the tissues. This increase of resistance should be taken into account in prolapse surgery: constraints are stronger than for stress incontinence. The posterior arms of meshes have to measure more than 1 cm wide and be set up through the sacrospinous ligament rather than through the elevator muscles. The type of knitting of prostheses is important and influences the resistance in tissues in the immediate postoperative time. Manufacturers should be interested in conceiving specific meshes for the tension-free fixation, with special and adapted mechanical properties.

Le texte complet de cet article est disponible en PDF.

Mots clés : Prolapsus, Incontinence urinaire, Résistance tissulaire, Treillis

Keywords : Prolapse, Urinary incontinence, Tissue resistance, Mesh


Plan


© 2007  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 1

P. 13-18 - janvier 2007 Retour au numéro
Article précédent Article précédent
  • Quelle place pour la radiopelvimétrie au XXIe siècle?
  • P. Rozenberg
| Article suivant Article suivant
  • Grossesse des patientes obèses: quels risques faut-il craindre?
  • G. Ducarme, A. Rodrigues, F. Aissaoui, C. Davitian, I. Pharisien, M. Uzan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.