S'abonner

Periprosthetic femoral fractures treated by locked plating: Feasibility assessment of the mini-invasive surgical option. A prospective series of 36 fractures - 14/10/11

Doi : 10.1016/j.otsr.2011.01.017 
M. Ehlinger a, , P. Adam a, A. Di Marco a, Y. Arlettaz b, B.-K. Moor b, F. Bonnomet a
a Department of Orthopaedic Surgery and Traumatology, Hautepierre Hospital, Strasbourg Academic Hospitals, 1, avenue Molière, 67098 Strasbourg cedex, France 
b Department of Orthopaedic Surgery and Musculo-skeletal Traumatology, Valais Canton Hospital, 80, avenue Grand-Champs-sec, 1951 Sion, Switzerland 

Corresponding author. Tel.: +33 3 88 12 77 19; fax: +33 3 88 12 77 13.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

The treatment of periprosthetic femoral fractures by conventional plating is associated with problems related to fracture union and eventual refracture. Additionally, locking nailing cannot be used in all cases because of the risk of malunion. To resolve these issues, locking plates have been proposed to combine the advantages of closed reduction and internal fixation while achieving a higher quality reduction with plate fixation.

Hypothesis

Locking plates put into place by a mini-invasive surgical approach result in fixation without substantial misalignment or non-union.

Patients and methods

From June 2002 to December 2007 we prospectively treated 35 patients (one bilateral), 28 women and seven men with a fracture around the hip implant (21), around the knee (8), between the hip implant and the knee (2), between a trochanteric internal fixation device and the knee implant (5). The mean age was 76, (39–93). Internal fixation was always attempted by mini-invasive surgery using locking plate system with locking screws (Synthès™). Rehabilitation included immediate weight bearing with as much weight as the patient would tolerate. The preoperative Parker score was 5.25 (0–9).

Results

There was one patient lost to follow-up, one early failure, and seven deaths (four of whom were included in the study group since their follow-up was at least 24 months) for a total of 31 fractures (30 patients), the mean follow-up for the series was 26 months (6–67). Twenty-six fixations were performed by mini-invasive approach and 10 through a conventional open surgery. Patients applied full weight (n=20), partial weight (n=3) or no weight for 6 weeks (n=13). Infections developed in two patients and there were three cases of mechanical failure. Fracture union was achieved in 35 out of 36 cases. More than 5° of misalignment was observed in five patients. Loosening of the implant did not occur in any patients during follow-up. The Parker score in patients seen at follow up was 4.3 (0–9).

Discussion-conclusion

Locking compression plates associated with a mini-invasive surgical approach result in a high rate of union (35/36) with no significant misalignment (only 5/36 cases of misalignment of more than 5°), no refractures (n=0) and a low rate of mechanical failure (3/36) while allowing full weight bearing in most cases (20/36). Locking plates for periprosthetic femoral fractures allow patients to begin walking again, with stable intermediate term results.

Level of scientific evidence

Level IV. Prospective study with no control group.

Le texte complet de cet article est disponible en PDF.

Keywords : Femoral fracture, Peri-prosthetic fracture, Locking plate, Mini-invasive


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 6

P. 622-628 - octobre 2011 Retour au numéro
Article précédent Article précédent
  • Components anteversion in primary cementless THA using straight stem and hemispherical cup: A prospective study in 91 hips using CT-scan measurements
  • O. Reikerås, R.B. Gunderson
| Article suivant Article suivant
  • Irreducible developmental dysplasia of the hip due to acetabular roof cartilage hypertrophy. Diagnostic sonography in 15 hips
  • C. Tréguier, C. Baud, M. Ferry, J.-L. Ferran, P. Darnault, M. Chapuis, S. Marleix, B. Fraisse, P. Violas

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.