S'abonner

Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating - 27/03/12

Doi : 10.1016/j.otsr.2011.09.023 
E. Sariali , R. Mauprivez, F. Khiami, H. Pascal-Mousselard, Y. Catonné
Department of orthopaedic surgery and traumatology, la Pitié-Salpétrière Hospital, 47–83 boulevard de l’hôpital, 154, rue de Picpus, 75012 Paris, France 

Corresponding author. Tel.: +33 6 03 00 83 94; fax: +33 1 42 17 74 15.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

A high accuracy was recently reported for the three-dimensional (3D) computerised planning of total hip arthroplasty (THA), comparing well with navigation regarding leg length and femoral offset. However, there is no randomised study comparing 3D preoperative planning with conventional 2D templating in terms of accuracy and clinical relevance.

Hypothesis

The 3D preoperative planning has a higher accuracy than the conventional 2D preoperative templating regarding the implants size and their positioning.

Patients and methods

A prospective comparative randomised study was carried out from 2008 to 2009, including two groups of 30 patients who underwent THA for primary osteoarthritis. One surgeon performed all the surgical procedures using a minimally invasive direct anterior approach. In one group, the planning was made on calibrated X-rays using 2D templates. In the other group, a CT-scan based 3D computerised planning was performed with dedicated software. The reconstructed hip final anatomy was compared postoperatively to the preoperative planning and the accuracy was expressed as the mean difference (±SD) between the planned positioning and the final positioning of the implants.

Results

The prediction rate for the stem and the cup sizes were respectively of 100% and 96% in the 3D group versus 43% for both components in the 2D group. When combining both components, the prediction rate was 96% in the 3D group versus 16% in the 2D group. In the 3D group, a high accuracy was achieved for the planning of the leg length (−1.8±3.6mm ranging from −8 to+4mm) and the femoral offset (−0.07±2.7mm ranging from −5 to+4mm) versus 1.37±6.4mm ranging from −9 to 13mm and 0.33±5.7mm (−16 to 11mm) in the 2D templating group (P<0.0001).

Discussion

The 3D planning gives a higher accuracy than conventional 2D templating in forecasting the size of cup and the stem. This contributes to the prediction for leg length and offset that is more reliable with the 3D technique. This study suggests that 3D planning CT-scan data is an attractive alternative to navigation to restore these parameters. The high accuracy achieved by a low-experience surgeon suggests that 3D planning may help shorten the learning curve when using the minimally invasive direct anterior approach.

Level of evidence

Level III low-powered prospective randomized trial.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Positioning criteria, Preoperative planning, Navigation


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 2

P. 151-158 - avril 2012 Retour au numéro
Article précédent Article précédent
  • Infected total hip arthroplasty revision: One- or two-stage procedure?
  • S. Klouche, P. Leonard, V. Zeller, L. Lhotellier, W. Graff, P. Leclerc, P. Mamoudy, E. Sariali
| Article suivant Article suivant
  • Reproducibility of an optical measurement system for the clinical evaluation of active knee rotation in weight-bearing, healthy subjects
  • R. Testa, J. Chouteau, A. Viste, L. Cheze, M.-H. Fessy, B. Moyen

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.