S'abonner

Reproducibility and reliability of subscapularis tendon assessment using CT-arthrography - 14/12/12

Doi : 10.1016/j.otsr.2012.07.014 
C. Szymanski , V. Staquet, J.Y. Deladerrière, T. Vervoort, S. Audebert, C. Maynou
Orthopaedics Department A, Roger-Salengro Hospital, 59037 Lille cedex, France 

Corresponding author. Tel.: +33 3 20 44 68 00.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 14 December 2012
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Background

Computed tomography (CT) coupled with arthrography remains the reference standard for the preoperative evaluation of rotator cuff tears. The objectives of this study were to evaluate intra-observer and inter-observer reproducibilities of CT-arthrographic assessment of the subscapularis tendon and to assess the validity and reliability of this investigation.

Hypothesis

CT-arthrography is reliable and reproducible for the preoperative characterisation of subscapularis tendon lesions.

Material and methods

We retrospectively reviewed 67 shoulders with rotator cuff tears in one or more tendons managed by arthroscopy, both to confirm the diagnosis and to allow therapeutic interventions. Each of the 67 preoperative CT-arthrograms was evaluated by three readers, of whom the first two evaluated the images twice at an interval of 30 days. The following were recorded at each reading: partial- or full-thickness tear in one or more rotator cuff tendons, intra-tendinous delamination, tendon stump retraction, and fatty degeneration of the muscles. The position of the long head of biceps tendon was assessed. A statistical analysis was performed using Fleiss’ method to compute intra-observer and inter-observer variabilities in CT-arthrography assessment of the subscapularis tendon status. Validity of this assessment was measured by computing the concordance coefficients between CT-arthrography and arthroscopy.

Results

Specificity of CT-arthrography was satisfactory for assessing the subscapularis tendon. Sensitivity was low. Significant inter-observer and intra-observer variabilities were documented. The concordance coefficients between CT-arthrography and arthroscopy indicated that major differences were common with all three readers. When assessing the subscapularis tendon by CT-arthrography, all readers experienced difficulties in distinguishing intact tendons, delaminated tendons, and tendons with tears confined to the upper third.

Discussion

Although CT-arthrography remains the reference standard for the preoperative investigation of rotator cuff tears, significant variability occurs in assessing the continuity of the subscapularis tendon. Reliability of this assessment is not optimal, as shown by our evaluation of concordance with arthroscopy. Although our data should be interpreted in the light of the investigation and measurement biases present in our study, they suggest that CT-arthrography may fail to provide a valid and reproducible assessment of the subscapularis tendon. The development of magnetic resonance (MR) imaging and MR-arthrography will probably improve the preoperative evaluation of subscapularis tears in the near future.

Level of evidence

Level III; diagnostic value study.

Le texte complet de cet article est disponible en PDF.

Keywords : Subscapularis, Computed tomography, Reliability, Rotator cuff imaging


Plan


© 2012  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.