S'abonner

Complex fractures of the distal humerus in the elderly: Is primary total elbow arthroplasty a valid treatment alternative? A series of 20 cases - 27/12/12

Doi : 10.1016/j.otsr.2012.10.010 
G. Ducrot a, , M. Ehlinger a, P. Adam a, A. Di Marco a, P. Clavert b, F. Bonnomet a
a Orthopaedic and Trauma Surgery Department, Hautepierre Hospital, Strasbourg University Hospitals, 1, avenue Molière, 67098 Strasbourg, France 
b Orthopaedic and Hand Surgery Centre, 10, avenue Achille-Baumann, 67400 Illkirch-Graffenstaden, France 

Corresponding author. Tel.: +33 03 88 12 77 23; fax: +33 03 88 12 77 13.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 27 December 2012
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

Distal humerus fractures are fairly rare. But as our population ages, these fractures become more complex and the choice of treatment more delicate. Poor bone quality results in many technical problems and the fixation hardware stability remains at risk. The goal of this study was to evaluate the functional recovery and morbidity of complex distal humerus fractures in elderly patients when treated with elbow prosthesis.

Hypothesis

Good functional recovery can be achieved with a total joint replacement.

Patients and methods

This series consisted of 20 patients (18 women and two men) having an average age of 80years (range 65–93, median 80). Based on the AO classification, there were two Type A2 fractures, two Type B fractures, 15 Type C fractures and one fracture that could not be classified because of previous rheumatoid disease history at this elbow. Two fractures were open. In two cases, the olecranon was also fractured. Treatment consisted of the implantation of a Coonrad-Morrey, hinge-type total elbow prosthesis (Zimmer®, Warsaw, IN, USA). The Mayo Clinic surgical approach was used 17 times and the transolecranon approach was used three times. Primary arthroplasty was performed in 19 cases and the surgery was performed after six weeks of conservative treatment (diagnostic delay) in one case. Unrestricted motion was allowed after surgery, but a maximum of 0.5kg could be carried during the first 3months; this was subsequently increased to 2.5kg.

Results

Fifteen of the 20 patients were available for reevaluation with an average follow-up of 3.6years (range 1.7–5.5, median 3.4). Four patients had died and one was lost to follow-up. The average range of motion was 97° (range 60–130°), comprising an average flexion of 130° (range 110–140°) and average loss of extension of 33° (range 0–80°). Pronation and supination were normal. The average Mayo Elbow Performance Score (MEPS) was 83 (range 60–100, median 80). X-rays revealed seven cases of radiolucent lines, with two being progressive. There was no visible wear of the polyethylene bushings at the hinge. Six patients had moderate periarticular heterotopic ossification. The two cases of olecranon osteotomy and one case of olecranon fracture had healed. There were no surgical site infections but two cases of ulnar compression, one of which required neurolysis. There was one case of humeral component loosening after 6years, but the implant was not changed.

Discussion

The clinical range of motion results were comparable to published data. The functional scores were slightly lower, mainly because of the pain factor. The initial results were encouraging and consistent with published data as long as the indications were well-chosen. Based on this retrospective study, total elbow arthroplasty can be a valid alternative in the surgeon’s treatment armamentarium for complex distal humerus fractures in elderly patients who have moderate functional demands. Our results support our hypothesis, since we found good functional recovery without associated morbidity.

Level of evidence

Level IV retrospective study without comparator.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal humeral fracture, Total elbow replacement, Elderly


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.