S'abonner

Three-dimensional finite element analysis of mini-external fixation and Kirschner wire internal fixation in Bennett fracture treatment - 02/02/13

Doi : 10.1016/j.otsr.2012.07.015 
L. Meng a, b, Y. Zhang c, Y. Lu a, d,
a Department of Orthopedics, Tianjin TEDA Hospital, Tianjin 300457, China 
b Graduate School of Tianjin Medical University, Tianjin 300070, China 
c Department of Orthopedic Trauma, Tianjin Hospital, Tianjin 300211, China 
d Department of Hand Microsurgery, Tianjin Hospital, Tianjin 300211, China 

Corresponding author. Department of Orthopedics, Tianjin TEDA Hospital, Number 65, Third Avenue, Tianjin TEDA, Tianjin 300457, China. Tel.: +86 22 65202200.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Objective

To analyze the mini-external fixation and percutaneous K-wire internal fixation for the treatment of Bennett fracture by using finite element analysis and to compare the biomechanical stability and postoperative impact of the two fixations on the fracture.

Methods

Three-dimensional digital models of the first metacarpal bone, second metacarpal bone, and the trapezium were established using Mimics 10.01 software. A solid model and finite element models were created and analyzed using ANSYS 10.0. The same load of 100N was exerted on both the mini-external fixator and the Kirschner (K)-wire internal fixator for the treatment of Bennett fracture. Finally, the none-line solution was analyzed, and displacement nephograms were obtained.

Results

The displacement nephograms of the distal and proximal fragments of the fracture obtained using the mini-external and K-wire models were established. The X/Y/Z (SUM)-component displacements of 15 nodes aligned with the articular surface fracture were obtained. The relative displacement of the distal and the proximal fragments of the fracture were calculated, and all digits of relative displacement were entered into SPSS 13.0 software. The difference between the X-component relative displacements was statistically significant. Moreover, the comparison of the Y-component, Z-component, and SUM-component relative displacements yielded statistical significance. The average relative displacement in the X-direction was 0.3214mm in the K-wire model.

Conclusion

Mini-external fixation is more effective than K-wire internal fixation for secure Bennett fracture stability. Both fixations have similar effects on postoperative traumatic arthritis and postoperative hand functions.

Level of evidence

1 Biomechanical studies.

Le texte complet de cet article est disponible en PDF.

Keywords : Bennett fracture, Fracture of the base of the first metacarpal, Finite element analysis, Mini-external fixation, K-wire internal fixation, Biomechanics, Finite element models


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 1

P. 21-29 - février 2013 Retour au numéro
Article précédent Article précédent
  • Complex fractures of the distal humerus in the elderly: Is primary total elbow arthroplasty a valid treatment alternative? A series of 20 cases
  • G. Ducrot, M. Ehlinger, P. Adam, A. Di Marco, P. Clavert, F. Bonnomet
| Article suivant Article suivant
  • Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up
  • G. Cinotti, A. Della Rocca, P. Sessa, F.R. Ripani, G. Giannicola

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.