S'abonner

Intraoperative determination of lumbar prosthesis endplate lordotic angulation to improve motion - 09/01/15

Doi : 10.1016/j.otsr.2014.11.008 
F. Laouissat a, , J. Allain b, J. Delécrin c
a Centre médico-chirurgical de réadaptation des massues, 92, rue Edmond-Locard, 69322 Lyon cedex 05, France 
b Service de chirurgie orthopédique et traumatologie, 51, avenue du Mal-de-Lattre-de-Tassigny, 94010 Créteil cedex, France 
c Service de chirurgie orthopédique et traumatologie, 1, place Alexis-Ricordeau, 4093 Nantes cedex 1, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 09 January 2015
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

The aim of total disc replacement (TDR) is to restore and maintain closer-to-physiology motion. Therefore, the factors that influence postoperative intervertebral motion have to be controlled. Factors such as disc height (DH), postoperative segmental lordosis (SL), implant design and positioning are still recognized to be influent. Otherwise, range of motion (ROM) distribution, between flexion and extension, appear to be influenced by obtaining parallel bearing surfaces, which depends on prosthesis endplate lordotic angulation. To assess in vivo the correlation between an intraoperative parameter (intraoperative segmental lordosis: ISL) and a postoperative parameter (postoperative segmental lordosis: PSL). To determine the advantage of ISL measurement on the improvement of the prosthetic endplate lordotic angulation choice. Radiological comparison between intraoperative and postoperative segmental parameters. Fifty-seven patients who received a TDR at one level, L4–L5 or L5–S1, with different prosthetic endplate lordotic angulations (0°, 5°, and 10°). Twenty-one consecutive patients underwent intraoperative measurement (ISL) on a lateral view, with a spacer at the mid-vertebral bony endplates (Group 1). ISL was correlated using a linear correlation test with PSL. Group 1 postoperative prosthesis endplate lordosis (PEL: angle between the bearing surfaces) were compared to those of 46 patients without intraoperative measurement (Group 2). The mean ISL and PSL angles were 12.2° (7–21°) and 13.9° (8–23°), respectively. We observed a strong linear correlation between ISL and PSL (r=0.78, P <0.006). In Group 1, PEL varied between −1° and 11°, and between −3.7° and 17.8° in Group 2. For 80% of the patients in Group 1, the PEL was less than 5°, versus 33% of the patients in Group 2. Only prostheses with PEL less than 5° had a preserved extension curve in ROM distribution (+3°). Intraoperative measurement of ISL has emerged as a key factor in predicting PSL in TDR. The percentage of parallel bearing surfaces was increased by a prosthesis endplate lordotic angulation choice guided by ISL measurement. This study confirmed the advantage of choosing the adequate lordotic angulation of the prosthesis endplate to restore a physiological motion distribution between flexion and extension.

Le texte complet de cet article est disponible en PDF.

Keywords : Lumbar total disc replacement, Intraoperative segmental lordosis, Prosthesis endplate lordotic angulation


Plan


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.