Abstract

Background

Intraoperative monitoring (IOM) has been proven to decrease the risk of neurological injury during scoliosis surgery. The vertical expandable prosthetic titanium rib (VEPTR) is a device that allows spinal growth. However, injuries to the spinal cord and brachial plexus have been reported after VEPTR implantation in 2 and 5% of patients, respectively. Simultaneous monitoring of these two structures requires the use of multiple time-consuming and complex methods that are ill-suited to the requirements of paediatric surgery, particularly when repeated VEPTR lengthening procedures are needed. We developed a monopolar stimulation method derived from Owen's monitoring technique. This method is easy to implement, requires only widely available equipment, and allows concomitant monitoring of the spinal cord and brachial plexus. The primary objective of this study was to assess the reliability of our technique for brachial plexus monitoring by comparing the stability of neurogenic mixed evoked potentials (NMEPs) at the upper and lower limbs.

Hypothesis

We hypothesised that the coefficients of variation (CVs) of NMEPs were the same at the upper and lower limbs.

Material and methods

Twelve VEPTR procedures performed in 6 patients between 1st January 2012 and 1st September 2014 were monitored using a monopolar stimulating probe. NMEPs were recorded simultaneously at the upper and lower limbs, at intervals of 150s. The recording sites were the elbow over the ulnar nerve and the popliteal fossa near the sciatic nerve. Wilcoxon's test for paired data was used to compare CVs of the upper and lower limb NMEPs on the same side.

Results

Mean CV of NMEP amplitude at the lower limbs was 16.34% on the right and 16.67% on the left; corresponding values for the upper limbs were 18.30 and 19.75%, respectively. Mean CVs of NMEP latencies at the lower limbs were 1.31% on the right and 1.19% on the left; corresponding values for the upper limbs were 1.96 and 1.73%. The risk of type I error for a significant difference between the upper and lower limbs was 0.5843 on the right and 0.7312 on the left for NMEP amplitudes and 0.7618 on the right and 0.4987 on the left for NMEP latencies.

Conclusion

Using an epidural active electrode and a sternal return electrode allows simultaneous stimulation of the cervical spinal cord and brachial plexus roots. The NMEPs thus obtained are as stable (reliable) at the upper limbs as at the lower limbs. This easy-to-implement method allows simultaneous monitoring of the upper and lower limbs. It seems well suited to VEPTR procedures.

Level of evidence

IV, retrospective single-centre non-randomised study.

Le texte complet de cet article est disponible en PDF.

Keywords : Monitoring, Intraoperative, Scoliosis, Paediatric patients, Evoked potentials, Motor


Plan


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 4S

P. S193-S197 - juin 2015 Retour au numéro
Article précédent Article précédent
  • Mobile-bearing versus fixed-bearing total knee implants. Results of a series of 100 randomised cases after 9 years follow-up
  • N. Poirier, P. Graf, F. Dubrana
| Article suivant Article suivant
  • Lateral elbow ligamentoplasty by autologous tendon graft in posterolateral rotatory instability: Results in 18 cases at a mean 5 years’ follow-up
  • E. Vernet, G. Bacle, E. Marteau, L. Favard, J. Laulan

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.