Reverse shoulder arthroplasty for proximal humerus fractures: Is the glenoid implant problematic?
 

Arthur Lignel a, , Julien Berhouet b, Marc-Alexandre Loirat a, Philippe Collin c, Hervé Thomazeau a, David Gallinet d, Pascal Boileau e, Luc Favard d
a CHU Pontchaillou, 35000 Rennes, France 
b CHU de Tours, 37000 Tours, France 
c CHP de Saint-Grégoire, 35760 Saint-Grégoire, France 
d Upper Limb Orthopedic Surgery University, 25000 Besançon, France 
e CHU de Nice, 06000 Nice, France 

Corresponding author.
Abstract
Introduction

Reverse shoulder arthroplasty (RSA) is a key tool in the orthopedic trauma surgeon's arsenal, especially when faced with a proximal humerus fracture in older patients. However, few studies have focused on the glenoid side of RSA in this indication as the implant is placed in a generally healthy scapula.

Hypothesis

Glenoid implants for RSA after trauma are well positioned and do not often cause complications.

Material and methods

Retrospective multicenter study of 513 patients who underwent RSA because of a proximal humerus fracture. The mean follow-up was 55 months. Radiographs were used to assess the height and tilt of the glenoid implant, along with the development of scapular notching or loosening. The clinical outcomes were determined based on the Constant score.

Results

At the last follow-up, 44% of shoulders had scapular notching, 7% of which were severe (stages 3–4). This notching was progressive, with two resulting in loosening. The rate of severe notching was higher in patients with a high glenoid implant (62.5% vs. 42.3%, p =0.03) or glenosphere with superior tilt (58.3% vs. 37.8%, p =0.02). Nine patients had confirmed loosening and 63 had potential loosening. This was more common in cases with superior tilt (9.3% vs. 0.4%, p <0.001). Patients with a high glenoid implant had a lower Constant score (57 vs. 45, p <0.001). There fewer cases of severe notching when a lateralized glenoid implant was used (0% vs. 7%, p <0.05) and/or the humeral implant had a smaller neck-shaft angle (implants<155°: 3% vs. implants at 155°: 8.5%, p =0.03).

Discussion and conclusion

Glenoid loosening and severe scapular notching are related to poor positioning and/or incorrect orientation of the glenosphere. Implant selection is important, as there is little to no notching when less-angled humeral implants and lateralized glenoid implants are used.

Level of evidence

IV.

The full text of this article is available in PDF format.

Keywords : Shoulder joint, Orthopedic Surgical Procedure, Traumatology, Joint Prosthesis




© 2018  Published by Elsevier Masson SAS.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline