Orthopaedics & Traumatology: Surgery & Research Volume 97, n° 3 pages 241-245 (mai 2011)
Doi : 10.1016/j.otsr.2010.07.012
accepted : 19 July 2010 Original articles
| | | Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty? | |
A. Viste a, b, ⁎ , J. Chouteau a, b, R. Testa a, b, L. Chèze a, M.-H. Fessy a, b, B. Moyen a, b
a IFSTTAR, LBMC UMRT 9406, INRETS, University Lyon 1, 43, Bolevard du 11-Novembre-1918, 69100 Villeurbanne, France b Traumatology and Sports Medicine Department, Department of Orthopaedic Surgery–Building 3A, Lyon Civilian Hospices South Lyon Hospital Center, Orthopaedic Surgery, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France
Corresponding author.Accurate positioning of the acetabular cup in primary total hip arthroplasty is critical to decrease the rate of dislocation. Inaccurate orientation of the cup is the most common error during this procedure. Target acetabular orientation is still controversial. An original study found a dislocation rate of 0.6% when the cup was aligned with the transverse acetabular ligament (TAL). TAL is a patient-specific anatomical landmark and a tool for cup orientation. Eight cadaveric pelves (14 hips included for study) were harvested in toto at our research laboratory. Anatomical versions of the TAL, labrum and horns were measured in relation to the anterior pelvic plane. A navigator sensor and an optoelectronic device (Motion Analysis™) were used. Anatomical versions of the TAL, horns and labrum averaged 1.9° (range, −8° to +13.3°), 3° (range, −12.2° to 14°), and 26.3° (range, 17.4° to 41.8°), respectively. To our knowledge, this is the first study to report the orientation of the periacetabular soft-tissues. TAL anteversion was outside the safe zone described by Lewinnek, while labrum anteversion was within this safe-zone. We discuss the reference used, Lewinnek’s safe zone, and functional orientation of the implants. Lewinnek’s safe-zone does not seem to be valid. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty. Level IV Prospective study.
Keywords : Total hip replacement, Dislocation, Transverse acetabular ligament, Cup orientation
| | Despite an increase in understanding of its causes and mechanisms, dislocation remains one of the main complications of primary total hip arthroplasty [1Huten D. Luxations et subluxations des prothèses totales de hanche Cahiers d’enseignements de la SOFCOT no 90: prothèses totales de hanche. Les choix Paris: Elsevier (2005).
370-417
Click here to see the Library]. Three factors are involved: the surgeon (approach [2Berry D.J., von Knoch M., Schleck C.D., Harmsen W.S. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty J Bone Joint Surg Am 2005 ; 87 : 2456-2463 [cross-ref]
Click here to see the Library, 3Woolson S.T., Rahimtoola Z.O. Risk factors for dislocation during the first 3 months after primary total hip replacement J Arthroplasty 1999 ; 14 : 662-668 [cross-ref]
Click here to see the Library], experience [4Hedlundh U., Ahnfelt L., Hybbinette C.H., Weckstrom J., Fredin H. Surgical experience related to dislocations after total hip arthroplasty J Bone Joint Surg Br 1996 ; 78 : 206-209
Click here to see the Library, 5Khatod M., Barber T., Paxton E., Namba R., Fithian D. An analysis of the risk of hip dislocation with a contemporary total joint registry Clin Orthop Relat Res 2006 ; 447 : 19-23 [cross-ref]
Click here to see the Library], orientation of components [6Ali Khan M.A., Brakenbury P.H., Reynolds I.S. Dislocation following total hip replacement J Bone Joint Surg Br 1981 ; 63 : 214-218
Click here to see the Library, 7Biedermann R., Tonin A., Krismer M., Rachbauer F., Eibl G., Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component J Bone Joint Surg Br 2005 ; 87 : 762-769 [cross-ref]
Click here to see the Library, 8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library]), the implants (ratio head/neck [2Berry D.J., von Knoch M., Schleck C.D., Harmsen W.S. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty J Bone Joint Surg Am 2005 ; 87 : 2456-2463 [cross-ref]
Click here to see the Library, 9Amstutz H.C., Le Duff M.J., Beaule P.E. Prevention and treatment of dislocation after total hip replacement using large diameter balls Clin Orthop Relat Res 2004 ; 429 : 108-116 [cross-ref]
Click here to see the Library], anti-dislocation devices [10Guyen O., Pibarot V., Vaz G., Chevillotte C., Bejui-Hugues J. Use of a dual mobility socket to manage total hip arthroplasty instability Clin Orthop Relat Res 2009 ; 467 : 465-472 [cross-ref]
Click here to see the Library]…) and the patient (age [3Woolson S.T., Rahimtoola Z.O. Risk factors for dislocation during the first 3 months after primary total hip replacement J Arthroplasty 1999 ; 14 : 662-668 [cross-ref]
Click here to see the Library], sex, alcohol consumption [11Paterno S.A., Lachiewicz P.F., Kelley S.S. The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement J Bone Joint Surg Am 1997 ; 79 : 1202-1210
Click here to see the Library], neurological history [12Ekelund A., Rydell N., Nilsson O.S. Total hip arthroplasty in patients 80 years of age and older Clin Orthop Relat Res 1992 ; 281 : 101-106
Click here to see the Library], history of surgery [13Fackler C.D., Poss R. Dislocation in total hip arthroplasties Clin Orthop Relat Res 1980 ; 151 : 169-178
Click here to see the Library]…). The position of the acetabular component is a central factor for preventing the risk of dislocation [14von Knoch M., Berry D.J., Harmsen W.S., Morrey B.F. Late dislocation after total hip arthroplasty J Bone Joint Surg Am 2002 ; 84 : 1949-1953
Click here to see the Library], as well as for limiting the risk of wear and loosening [15Kennedy J.G., Rogers W.B., Soffe K.E., Sullivan R.J., Griffen D.G., Sheehan L.J. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration J Arthroplasty 1998 ; 13 : 530-534 [cross-ref]
Click here to see the Library]. The orientation of the cup is defined by its inclination and version. Unlike inclination, which according to most authors should be approximately 45° [7Biedermann R., Tonin A., Krismer M., Rachbauer F., Eibl G., Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component J Bone Joint Surg Br 2005 ; 87 : 762-769 [cross-ref]
Click here to see the Library, 8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library, 16Dorr L.D., Wolf A.W., Chandler R., Conaty J.P. Classification and treatment of dislocations of total hip arthroplasty Clin Orthop Relat Res 1983 ; 173 : 151-158
Click here to see the Library, 17McCollum D.E., Gray W.J. Dislocation after total hip arthroplasty. Causes and prevention Clin Orthop Relat Res 1990 ; 261 : 159-170
Click here to see the Library] for optimal range of movement, implant stability and to limit wear, there is no consensus about how much anteversion is necessary for the cup. Murray [18Murray D.W. The definition and measurement of acetabular orientation J Bone Joint Surg Br 1993 ; 75 : 228-232
Click here to see the Library] defined three types of cup anteversion: anatomical, operative and radiographic. Anteversion values are different depending on the plane of reference, and Murray has developed conversion nomograms for these three definitions. [18Murray D.W. The definition and measurement of acetabular orientation J Bone Joint Surg Br 1993 ; 75 : 228-232
Click here to see the Library]. McKibbin [19McKibbin B. Anatomical factors in the stability of the hip joint in the newborn J Bone Joint Surg Br 1970 ; 52 : 148-159
Click here to see the Library] was the first to use the anterior pelvic plane (APP) (plane which passes through the two anterosuperior iliac spines and in the middle of the pubic tubercles) to measure acetabular anteversion. Lewinnek et al. [8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library] defined a “safe zone” defined from the APP (between 5 and 25° of radiographic anteversion) to reduce the rate of dislocation (1.5% vs 6%). During surgery, the most important step is cup orientation, especially for young surgeons. The position on the operating table, dislocation of the native hip and the use of retractors all change pelvic, and thus acetabular version [20Murtha P.E., Hafez M.A., Jaramaz B., DiGioia A.M. Variations in acetabular anatomy with reference to total hip replacement J Bone Joint Surg Br 2008 ; 90 : 308-313 [cross-ref]
Click here to see the Library]. During traditional surgery, there are no reliable constants: table position (transverse axis), patient’s body (longitudinal axis). Computer assisted surgery has not solved this problem because except in cases of kinematic navigation, there is the problem of which reference to use for the subject in the decubitus position [21Laffargue P., Pinoit Y., Tabutin J., Giraud F., Puget J., Migaud H. Computer-assisted positioning of the acetabular cup for total hip arthroplasty based on joint kinematics without prior imaging: preliminary results with computed tomographic assessment Rev Chir Orthop 2006 ; 92 : 316-325 [inter-ref]
Click here to see the Library]. An original study in 2006 by Archbold et al. [22Archbold H.A., Mockford B., Molloy D., McConway J., Ogonda L., Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability J Bone Joint Surg Br 2006 ; 88 : 883-886 [cross-ref]
Click here to see the Library] reported a rate of dislocation of 0.6% (posterolateral approach, 28mm heads) at a minimum of 8 months of follow-up if the cup component was placed parallel to the transverse acetabular ligament (TAL). The TAL is a fibrocartilaginous tissue, which unites the two horns of the acetabular notch. This ligament is usually found (99.7%) even in cases of severe osteoarthritis of the hip (after removing osteophytes) [22Archbold H.A., Mockford B., Molloy D., McConway J., Ogonda L., Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability J Bone Joint Surg Br 2006 ; 88 : 883-886 [cross-ref]
Click here to see the Library]. However, to our knowledge, there is no anatomical study which has evaluated the orientation of the transverse ligament and its variations. We measured anatomical anteversion of the TAL in relation to the APP. We then compared these results to those of Lewinnek et al. [8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library] in order to discuss the reliability of using the TAL as an anatomical reference for positioning cups during primary total hip arthroplasty. Eight fresh in toto cadaveric pelves (including sacroiliac joints, pubic ligaments, labrum and TAL) were harvested from the laboratory of anatomy in Lyon: three men and five women. The mean age was 82.5±3.3 years (range 78–93). Only “normal” pelves were included in this study for a total of 14 acetabuli. Acetabuli with osteoarthritis of the hip, prior injury or hip surgery were excluded. Once dissected and harvested, the fresh pelves were frozen until the experimental phase of the study. The pelves were thawed 24hours before being studied to restore the texture to the TAL and the labrum. Measurements were obtained with an optoelectronic system with passive markers called Motion Analysis™ (Santa Rosa, California, USA). Six Eagle™ cameras (1.3Mpx) were piloted by EVaRT 5.0™ software. An appropriate volume was chosen around the pelves. Static and dynamic calibrations were obtained. System errors were below 0.2mm. The sampling frequency of the cameras was 100Hz. A Butterworth filter was used (low pass, order 5, cut-off frequency 6Hz) to correct the 3D path of the markers. Six markers (diameter 12mm) were glued onto each pelvis with Loctite™ (Henkel, Marne-la-Vallée, France). Two were attached to the posterosuperior iliac spines ((PSIS-R) and (PSIS-L)-M), two to the anterosuperior iliac spines (ASIS-R and ASIS-L) and two to the pubic tubercles (PUB-L and PUB-R). The BrainLab™ tracking sensor and three markers were used to measure the different elements (Figure 1). The exact dimensions were known (manufacturer’s specifications).
|
| | 
| Figure 1. Tracking of the transverse acetabular ligament. ASIS: anterosuperior iliac spine. PUB: pubic tubercles. R: right, L: left. Zoom | Both acetabuli were studied for each pelvis. It was important that the operator (the same orthopedic surgeon for all pelves) be careful to keep the tracking sensor in contact with the zone being studied. There were three consecutive acquisition sequences for each hip; TAL, horns and labrum. The entire TAL and labrum were palpated with the tracking sensor (for 5 and 10s, respectively), and the horns were tracked on their most prominent area. EvaRT 5.0™ software calculated the 3D coordinates of the tracking markers at a main static reference point which was determined during calibration of the device. The Skeleton builder™ module integrated into the software was used to hierarchically define the objects being studied. In this way, it was possible to identify the position of an object in relation to another hierarchically superior object. The original position of the lowest object was provided by three coordinates and the orientation of this object was given by three angles. An initial object was defined by its reference point created with the help of the markers ASIS-R, ASIS-L, PUB-R and PUB-L. The origin O was at the level of the pubis between the two markers PUB-R and PUB-L. The Y-axis was found between the origin O and the middle of ASIS-R and ASIS-L. The Z-axis was coplanar to the Y-axis, in the plane defined by PUB-R, PUB-L and ASIS-R and the Z-axis oriented towards the right. The X-axis was defined to create a direct orthonormal reference with Y and Z (with X towards the front). This reference was called the APP (Figure 2). A second object was then defined at the level of the marker. The origin of this reference was the tip of the tracking sensor. Thanks to Skeleton™, the position of the origin of the tracking sensor was found directly in the reference APP.
|
| | 
| Figure 2. Anterior pelvic plane (blue) and orthonormal reference (O, X, Y, Z). Zoom |
| |
| Calculations and data analysis | The necessary data were obtained during the tracking phase. Once data were processed with EvaRT™, they were exported to format.htr. An Excel™ macro was then used to recover the 3D coordinates of the origin of the tracking device in the reference APP which was calculated over time using Skeleton™. Then by projecting these coordinates onto the XZ plane (transversal plane perpendicular to the APP), we calculated the anatomical anteversion of the TAL, the acetabular horns and the labrum. Anatomical anteversion was the anteversion measured in this transversal plane between the sagittal X-axis and the line corresponding to projection of the plane of interest (Figure 3). We calculated the line of regression (least squares regression) using the scatter plot of points obtained by the tracker on the TAL, and projected this onto the transversal plane (O, X, Z). We did the same thing with the scatter plot points obtained on the posterior and anterior horns (CP and CA). For the labrum, a plane of least squares was determined from the scatterplot obtained: the labral plane. Then the line that intersected the labral plane and the (O, X, Z) plane was determined. The anatomical anteversion was obtained from the arctangent of the slope of the line.
|
| | 
| Figure 3. Definition of the anatomical angle of anteversion ⍺ [18Murray D.W. The definition and measurement of acetabular orientation J Bone Joint Surg Br 1993 ; 75 : 228-232
Click here to see the Library]. Zoom | This study included 14 acetabuli after excluding two hips that had former surgery. The anatomical version of the TAL was between −8° and +13.3° (mean=+1.9°) (Table 1). The anatomical version of the horns was between −12.2° and +14° (mean=+3°) (Table 1). The anatomical version of the acetabular labrum was +17°±41.8° (mean=+26.3°) (Table 1). Pelves 1 and 5 presented with ligaments and horns with the greatest retroversion of approximately −10°. There was anteversion in the labrum in all hips. Since the study by Archbold et al. [22Archbold H.A., Mockford B., Molloy D., McConway J., Ogonda L., Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability J Bone Joint Surg Br 2006 ; 88 : 883-886 [cross-ref]
Click here to see the Library], the TAL has become an important reference for certain surgeons for hip arthroplasty. These authors identified a TAL in 99.7% of their interventions. The TAL has become one of the main anatomical references for positioning the cup both in traditional and computer-assisted surgery. Thus, this study was needed to confirm the reliability of this element as a reference point. To our knowledge, there are no other studies in the literature on the anatomical orientation of the “soft tissues” (transverse ligament, labrum) around the acetabulum. Moreover, most studies evaluating the orientation of total hip arthroscopy components are based on radiography whose parameters are not standardized. We chose the APP because this is an “anatomical” plane which is used in most publications [7Biedermann R., Tonin A., Krismer M., Rachbauer F., Eibl G., Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component J Bone Joint Surg Br 2005 ; 87 : 762-769 [cross-ref]
Click here to see the Library, 23Rittmeister M., Callitsis C. Factors influencing cup orientation in 500 consecutive total hip replacements Clin Orthop Relat Res 2006 ; 445 : 192-196
Click here to see the Library, 24Pearce C.J., Sexton S.A., Davies D.C., Khaleel A. The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty Hip Int 2008 ; 18 : 7-10
Click here to see the Library] and which has reference values determined by Lewinnek et al. [8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library] We converted the radiographic anteversion values (15±10°) into anatomical anteversion (35±20°) using Murray’s conversion nomograms [18Murray D.W. The definition and measurement of acetabular orientation J Bone Joint Surg Br 1993 ; 75 : 228-232
Click here to see the Library]. The APP was chosen despite the controversy about the functional notion of pelvic tilt. Pelvic version modifies acetabular orientation [25Lazennec J.Y., Charlot N., Gorin M., Roger B., Arafati N., Bissery A., and al. Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning Surg Radiol Anat 2004 ; 26 : 136-144
Click here to see the Library]. When pelvic version increases, acetabular anteversion decreases and vice versa. When standing, the anterior pelvic plan is not vertical because of this variation in pelvic version. Nevertheless, this is one of the only anatomical pelvic planes which is easily measured in vitro.
| |
| Transverse acetabular ligament and the anterior pelvic plane | An MRI study by Archbold et al. [26Archbold H.A., Slomczykowski M., Crone M., Eckman K., Jaramaz B., Beverland D.E. The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty Hip Int 2008 ; 18 : 1-6
Click here to see the Library] showed that mean anteversion (surgical anteversion) of a TAL-labrum plane was similar to that of the labrum in our study. (approximately 23°). On the other hand, our study does not support the use of a common TAL-labrum plane because we observed different anterversion for these two structures. A radiographic study by Pearce et al. [24Pearce C.J., Sexton S.A., Davies D.C., Khaleel A. The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty Hip Int 2008 ; 18 : 7-10
Click here to see the Library] showed that the TAL was a reliable reference for aligning the cup in Lewinnek’s safe zone. However, this study was based on non-standardized X-rays. Our study did not confirm these results, because orientation using the TAL with reference to the APP was not in Lewinnek’s safe zone. Our study showed that orientation of the TAL (and the horns) was outside of (below) Lewinnek’s “safe zone”. On the other hand, labral anteversion was found to be within this zone. Based on these results, in order to be within Lewinnek’s safe zone, the cup should have 30° of anterversion in relation to the TAL plane. Lewinnek et al. [8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library] analysed 113 X-rays with only nine patients with dislocation. These authors identified 1.5% of cases with dislocation in the “safe zone” which is twice as many as the study by Archbold et al. [22Archbold H.A., Mockford B., Molloy D., McConway J., Ogonda L., Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability J Bone Joint Surg Br 2006 ; 88 : 883-886 [cross-ref]
Click here to see the Library] which used the TAL as a reference. The limits of our study are the lack of power of our statistical tests. A study of variations scatterplot in TAL anteversion in a larger population would make it possible to draw conclusions about the intra-individual specificity of this reference. Our study only evaluated cup anteversion, and it is obvious that when trying to reduce dislocation, femoral stem anteversion, which is easier to evaluate during surgery, is complementary to that of the cup (notion of combined anteversion). [27Barsoum W.K., Patterson R.W., Higuera C., Klika A.K., Krebs V.E., Molloy R. A computer model of the position of the combined component in the prevention of impingement in total hip replacement J Bone Joint Surg Br 2007 ; 89 : 839-845 [cross-ref]
Click here to see the Library]. Moreover, the tilt of the structures studied could result in variations in the projected anteversion. Finally, because this was an anatomical study, we did not take into account the lumbar-pelvic complex, whose balance affects the orientation of the acetabulum depending on the patient’s position (sitting, standing, lying down…) [28DiGioia A.M., Hafez M.A., Jaramaz B., Levison T.J., Moody J.E. Functional pelvic orientation measured from lateral standing and sitting radiographs Clin Orthop Relat Res 2006 ; 453 : 272-276 [cross-ref]
Click here to see the Library]. Our study showed that TAL anteversion was outside (below) Lewinnek’s safe zone. This standard should not be used to position cups between 5 and 25° in relation to the APP. Like Archbold et al. [22Archbold H.A., Mockford B., Molloy D., McConway J., Ogonda L., Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability J Bone Joint Surg Br 2006 ; 88 : 883-886 [cross-ref]
Click here to see the Library, 26Archbold H.A., Slomczykowski M., Crone M., Eckman K., Jaramaz B., Beverland D.E. The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty Hip Int 2008 ; 18 : 1-6
Click here to see the Library] and Biedermann et al. [7Biedermann R., Tonin A., Krismer M., Rachbauer F., Eibl G., Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component J Bone Joint Surg Br 2005 ; 87 : 762-769 [cross-ref]
Click here to see the Library], we believe that cup orientation should be specific for each patient and not a universal standard as suggested by Lewinnek et al. [8Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220
Click here to see the Library]. Indeed, anteversion is not a static parameter but a specific dynamic value for each individual. Moreover, the APP varies significantly in relation to the vertical plan depending on the patient’s position (sitting, standing, lying down…) [29Pinoit Y., May O., Girard J., Laffargue P., Ala Eddine T., Migaud H. Low accuracy of the anterior pelvic plane to guide the position of the cup with imageless computer assistance: variation of position in 106 patients Rev Chir Orthop 2007 ; 93 : 455-460 [inter-ref]
Click here to see the Library, 30Philippot R., Wegrzyn J., Farizon F., Fessy M.H. Pelvic balance in sagittal and Lewinnek reference planes in the standing, supine and sitting positions Orthop Traumatol Surg Res 2009 ; 95 : 70-76 [cross-ref]
Click here to see the Library]. Lewinnek’s notion is static, standard and therefore incorrect. Anatomical anteversion of the TAL in the APP is approximately 0±10°. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty.
|
|
Conflict of interest statement | No conflict of interest. | | | |
| Huten D. Luxations et subluxations des prothèses totales de hanche Cahiers d’enseignements de la SOFCOT n o 90: prothèses totales de hanche. Les choix Paris: Elsevier (2005).
370-417 | | | Berry D.J., von Knoch M., Schleck C.D., Harmsen W.S. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty J Bone Joint Surg Am 2005 ; 87 : 2456-2463 [cross-ref] | | | Woolson S.T., Rahimtoola Z.O. Risk factors for dislocation during the first 3 months after primary total hip replacement J Arthroplasty 1999 ; 14 : 662-668 [cross-ref] | | | Hedlundh U., Ahnfelt L., Hybbinette C.H., Weckstrom J., Fredin H. Surgical experience related to dislocations after total hip arthroplasty J Bone Joint Surg Br 1996 ; 78 : 206-209 | | | Khatod M., Barber T., Paxton E., Namba R., Fithian D. An analysis of the risk of hip dislocation with a contemporary total joint registry Clin Orthop Relat Res 2006 ; 447 : 19-23 [cross-ref] | | | Ali Khan M.A., Brakenbury P.H., Reynolds I.S. Dislocation following total hip replacement J Bone Joint Surg Br 1981 ; 63 : 214-218 | | | Biedermann R., Tonin A., Krismer M., Rachbauer F., Eibl G., Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component J Bone Joint Surg Br 2005 ; 87 : 762-769 [cross-ref] | | | Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmerman J.R. Dislocations after total hip-replacement arthroplasties J Bone Joint Surg Am 1978 ; 60 : 217-220 | | | Amstutz H.C., Le Duff M.J., Beaule P.E. Prevention and treatment of dislocation after total hip replacement using large diameter balls Clin Orthop Relat Res 2004 ; 429 : 108-116 [cross-ref] | | | Guyen O., Pibarot V., Vaz G., Chevillotte C., Bejui-Hugues J. Use of a dual mobility socket to manage total hip arthroplasty instability Clin Orthop Relat Res 2009 ; 467 : 465-472 [cross-ref] | | | Paterno S.A., Lachiewicz P.F., Kelley S.S. The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement J Bone Joint Surg Am 1997 ; 79 : 1202-1210 | | | Ekelund A., Rydell N., Nilsson O.S. Total hip arthroplasty in patients 80 years of age and older Clin Orthop Relat Res 1992 ; 281 : 101-106 | | | Fackler C.D., Poss R. Dislocation in total hip arthroplasties Clin Orthop Relat Res 1980 ; 151 : 169-178 | | | von Knoch M., Berry D.J., Harmsen W.S., Morrey B.F. Late dislocation after total hip arthroplasty J Bone Joint Surg Am 2002 ; 84 : 1949-1953 | | | Kennedy J.G., Rogers W.B., Soffe K.E., Sullivan R.J., Griffen D.G., Sheehan L.J. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration J Arthroplasty 1998 ; 13 : 530-534 [cross-ref] | | | Dorr L.D., Wolf A.W., Chandler R., Conaty J.P. Classification and treatment of dislocations of total hip arthroplasty Clin Orthop Relat Res 1983 ; 173 : 151-158 | | | McCollum D.E., Gray W.J. Dislocation after total hip arthroplasty. Causes and prevention Clin Orthop Relat Res 1990 ; 261 : 159-170 | | | Murray D.W. The definition and measurement of acetabular orientation J Bone Joint Surg Br 1993 ; 75 : 228-232 | | | McKibbin B. Anatomical factors in the stability of the hip joint in the newborn J Bone Joint Surg Br 1970 ; 52 : 148-159 | | | Murtha P.E., Hafez M.A., Jaramaz B., DiGioia A.M. Variations in acetabular anatomy with reference to total hip replacement J Bone Joint Surg Br 2008 ; 90 : 308-313 [cross-ref] | | | Laffargue P., Pinoit Y., Tabutin J., Giraud F., Puget J., Migaud H. Computer-assisted positioning of the acetabular cup for total hip arthroplasty based on joint kinematics without prior imaging: preliminary results with computed tomographic assessment Rev Chir Orthop 2006 ; 92 : 316-325 [inter-ref] | | | Archbold H.A., Mockford B., Molloy D., McConway J., Ogonda L., Beverland D. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability J Bone Joint Surg Br 2006 ; 88 : 883-886 [cross-ref] | | | Rittmeister M., Callitsis C. Factors influencing cup orientation in 500 consecutive total hip replacements Clin Orthop Relat Res 2006 ; 445 : 192-196 | | | Pearce C.J., Sexton S.A., Davies D.C., Khaleel A. The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty Hip Int 2008 ; 18 : 7-10 | | | Lazennec J.Y., Charlot N., Gorin M., Roger B., Arafati N., Bissery A., and al. Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning Surg Radiol Anat 2004 ; 26 : 136-144 | | | Archbold H.A., Slomczykowski M., Crone M., Eckman K., Jaramaz B., Beverland D.E. The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty Hip Int 2008 ; 18 : 1-6 | | | Barsoum W.K., Patterson R.W., Higuera C., Klika A.K., Krebs V.E., Molloy R. A computer model of the position of the combined component in the prevention of impingement in total hip replacement J Bone Joint Surg Br 2007 ; 89 : 839-845 [cross-ref] | | | DiGioia A.M., Hafez M.A., Jaramaz B., Levison T.J., Moody J.E. Functional pelvic orientation measured from lateral standing and sitting radiographs Clin Orthop Relat Res 2006 ; 453 : 272-276 [cross-ref] | | | Pinoit Y., May O., Girard J., Laffargue P., Ala Eddine T., Migaud H. Low accuracy of the anterior pelvic plane to guide the position of the cup with imageless computer assistance: variation of position in 106 patients Rev Chir Orthop 2007 ; 93 : 455-460 [inter-ref] | | | Philippot R., Wegrzyn J., Farizon F., Fessy M.H. Pelvic balance in sagittal and Lewinnek reference planes in the standing, supine and sitting positions Orthop Traumatol Surg Res 2009 ; 95 : 70-76 [cross-ref] | |
| | | | | |
© 2011
Elsevier Masson SAS. All Rights Reserved. | | | | |
|