Treatment of ruptured intra-cranial internal carotid artery dissection using a flow-diverter stent
Dissection rompue de l’artère carotide interne intracrânienne traitée par mise en place d’un stent « flow-diverter »
 

Guilherme S. Nakiri a, Maher Al-Khawaldeh a, Bruno Parente b, Iruena Kessler b, Benjamin Gory a, Roberto Riva a, Charbel Mounayer a,
a Department of Interventional Neuroradiology, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges, France 
b Department of Interventional Neuroradiology, University of Brasília, Brasília, Brazil 

Corresponding author.
Summary

In the presence of associated subarachnoid hemorrhage, the treatment of arterial dissection can be classified as either deconstructive (involving occlusion or sacrifice of the parent vessel) or reconstructive (preserving blood-flow through the parent vessel). In both treatment strategies, the main goal is to prevent any further risk of rebleeding. However, reconstructive treatment is reserved only for those patients in whom occlusion of the parent vessel is not feasible due to an insufficient collateral supply.

This report is of a case of intra-cranial carotid artery dissection treated by a reconstructive endovascular approach, with deployment of a flow-diverter stent, for the management of an associated subarachnoid hemorrhage. This is, to the authors’ knowledge, the first report of the use of a flow-diverter device as the main treatment of a ruptured supraclinoid carotid artery dissection.


Keywords : Flow-diverter stents, Intra-cranial dissection, Endovascular treatment, Subarachnoid hemorrhage




© 2011  Published by Elsevier Masson SAS.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline
You can move this window by clicking on the headline