Perfusion magnetic resonance imaging: Comparison of semiologic characteristics in first-pass perfusion of brain tumors at 1.5 and 3 Tesla
IRM de perfusion : comparaison des caractéristiques sémiologiques des tumeurs cérébrales à 1,5T et 3T
 

Natacha Mauz a , Alexandre Krainik a , Irène Tropres b , Laurent Lamalle b , Elodie Sellier c , Omer Eker a , Florence Tahon a , Jean-François Le Bas a , Sylvie Grand a,
a Clinique universitaire de neuroradiologie et IRM, CHU de Grenoble, BP 217, 38043 Grenoble cedex 9, France 
b Structure fédérative de recherche, université Joseph-Fourier–Site santé, Grenoble institut de neurosciences, bâtiment Edmond-J.-Safra, chemin Fortuné-Ferrini, 38706 La Tronche cedex, France 
c Unité de qualitique et d’évaluation médicale, CHU de Grenoble, BP 217, 38043 Grenoble cedex 9, France 

Corresponding author.
Summary
Objectives

To investigate whether using 3 Tesla (T) instead of 1.5T modifies the data obtained from first-pass perfusion in relation to the quantitative values of cerebral blood volume (CBV) and estimation of micro-vascular leakage (MVL). To describe the differences in data in the setting of neuro-oncology cases and propose explanations based on the discrepancies.

Material and methods

In total, 21 patients presenting an intracranial intra-axial space-occupying lesion underwent two MRI explorations, one at 1.5T and another at 3T, including a first-pass perfusion sequence using sequence parameters, defined by the manufacturer Philips. Using a gamma variate analysis, the ratio of cerebral blood volume (rCBV) in tumor, peritumoral, and normal appearing areas was first assessed. After a global analysis, a subgroup analysis was conducted according to the rCBV value measured at 1.5T. Lastly, MVL was assessed based on the signal intensity recorded above baseline after the passage of the contrast medium.

Results

At 3T, compared to 1.5T data that are currently the reference, rCBV was constantly and significantly over-evaluated (P =0.0041 for all tumors), while MVL was constantly and significantly under-evaluated (P <0.0001 for all tumors).

Discussion

The increase in magnetic field strength along with the associated modifications in sequence parameters led to variations in rCBV and MVL when measured using first-pass perfusion. In some cases, such as lymphomas, there was a loss of diagnostic information. It therefore appears necessary to optimize the acquisition parameters to allow for radiologic semiology to become relevant again.


Keywords : MRI, Perfusion, Brain tumors, 1.5T, 3T




© 2012  Elsevier Masson SAS. All Rights Reserved.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline