Suscribirse

Multicentre randomized controlled trial with sensor-augmented pump vs multiple daily injections in hospitalized patients with type 2 diabetes in China: Time to reach target glucose - 22/02/17

Doi : 10.1016/j.diabet.2016.12.009 
W. Gu a, 1, 2 , Y. Liu b, 1, 3 , Y. Chen c, 4 , W. Deng d, 5 , X. Ran e, 6 , L. Chen f, 7 , D. Zhu g, 6 , J. Yang h, 5 , J. Shin i, 8 , S.W. Lee i, 9 , T.L. Cordero i, 10 , Y. Mu a,
a Chinese PLA General Hospital, No. 28, Fuxing Road, Beijing, China 
b The Second Hospital of Jilin University, No. 218, Ziqiang Street, Nanguan District, Changchun, Jilin Province, China 
c Fu Wai Hospital CAMS & PUMC, 167 Beilishi Road, Xi Cheng District, Beijing, China 
d Beijing Jishuitan Hospital, No. 31, Xin Jie Kou Eastern Street, Western District, Beijing, China 
e West China Hospital-Sichuan University, No. 37, Guoxue Alley, Chengdu, Sichuan Province, China 
f Union Hospital Tongji Medical College, No. 1277, Jiefang Avenue, Wuhan, Hubei Province, China 
g Nanjing Drum Tower Hospital, Nanjing University Medical School, No. 321, Zhongshan, Nanjing, China 
h Beijing Tongren Hospital, Capital Medical University, No. 1, Dong Jiao Min Xiang, Eastern District, Beijing, China 
i Medtronic, 18000 Devonshire Street, Northridge, CA 91325, United States 

Corresponding author. Tel.: +86 10 5549 9001.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Wednesday 22 February 2017
This article has been published in an issue click here to access

Abstract

Aim

Sensor-augmented pump (SAP) technology, which combines continuous subcutaneous insulin infusion (CSII) and real-time continuous glucose monitoring (RT-CGM), has been available for several years in China. In this study, the time required to reach predefined glycaemic targets with SAP vs multiple daily injection (MDI) therapy was compared in hospitalized patients with type 2 diabetes mellitus (T2DM).

Methods

Adults (aged 18–65 years) with T2DM treated with insulin and admitted to hospital for glucose management were randomized to either SAP (Medtronic MiniMed™ Paradigm™ 722 system) or MDI with blinded CGM (Medtronic MiniMed CGMS System Gold™) for a 2-week period. Glycaemic targets were defined as three preprandial measurements between 80 and 130mg/dL (4.4 and 7.2mmol/L) and three 2-h postprandial measurements between 80 and 180mg/dL (4.4 and 10.0mmol/L) within the same day.

Results

When data from 81 patients (40 SAP, 41 MDI) were analysed, 21 patients using SAP therapy, compared with six using MDI therapy, achieved their glycaemic targets within 3 days, and their time to reach their glucose targets was significantly shorter (3.7±1.1 vs 6.3±3.1 days for MDI; P<0.001), while three MDI patients failed to reach glycaemic targets within 14 days. SAP vs MDI patients experienced significantly less hypoglycaemia [sensor glucose<50mg/dL (2.8mmol/L): 0.04% vs 0.32%, respectively; P<0.05] and significantly less hyperglycaemia [sensor glucose>180mg/dL (10mmol/L): 21.56% vs 35.03%, respectively; P<0.05].

Conclusion

SAP vs MDI therapy in hospitalized patients with T2DM significantly reduced the time required to achieve glycaemic targets, and such systems may be a cost-effective way to improve glucose control and reduce hospital stays in T2DM patients.

El texto completo de este artículo está disponible en PDF.

Keywords : Continuous glucose monitoring, Hospitalized, Multiple daily injections, Sensor-augmented pump, Short-term intensive insulin, Type 2 diabetes


Esquema


 Clinical Trials.gov number: NCT01921322.


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.