Índice Suscribirse

Techniques et principes des tomographies en cohérence optique - 27/09/18

Techniques and principles of optical coherence tomography

[21-045-A-15]  - Doi : 10.1016/S0246-0343(18)64331-X 
M. Streho, MD, FEBO a, b, e, , F. Matonti, MD, PHD, FEBO c, d
a Centre Explore Vision, 12, rue Croix-des-Petits-Champs, 75001 Paris, France 
b Service d'ophtalmologie du Pr Tadayoni, Hôpital Lariboisière, 2, rue Ambroise-Paré, 75475 Paris cedex 10, France 
c Institut de neurosciences de la Timone, Aix-Marseille Université, CNRS, 27, boulevard Jean-Moulin, 13385 Marseille cedex 05, France 
d Département d'ophtalmologie, Hôpital Nord, AP-HM, chemin des Bourrely, 13015 Marseille, France 
e Centre Explore Vision, 4, rue des Grandes Terres, 92500 Rueil-Malmaison, France 

Auteur correspondant.

Article à jour au 08/12/2022

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 9
Iconografías 8
Vídeos 0
Otros 0

Resumen

La tomographie en cohérence optique (OCT) a été la révolution de l'imagerie oculaire des dernières années. Initialement développé pour mesurer l'épaisseur maculaire dans le suivi des œdèmes maculaires diabétiques, cet appareil s'est révélé être l'outil indispensable pour une analyse quasi histologique de l'œil. En effet, en utilisant un faisceau lumineux balayant la rétine (ou autres structures), l'OCT permet d'établir une image selon différents degrés de réflectivités correspondant aux différentes couches cellulaires avec une résolution actuellement autour de 5 à 10 μm. De plus, cette technique possède quasiment tous les avantages : non invasif, rapide, fiable, reproductible et délégable. Ce qui explique son formidable développement et sa généralisation à une activité ophtalmologique spécialisée mais également générale. La France est probablement le pays au monde le plus équipé en OCT, ce qui fait des ophtalmologistes français des utilisateurs chevronnés. Pour en retirer le maximum, il convient de bien connaître les principes techniques et les différentes évolutions ainsi que les points-clés pour la réalisation et l'interprétation de l'examen. Cet article est la mise à jour de « Technique et interprétation de l'optical coherence tomography ».

El texto completo de este artículo está disponible en PDF.

Abstract

Optical coherence tomography (OCT) has been the eye-imaging revolution of recent years. Initially developed to measure macular thickness in the monitoring of diabetic macular edema, this device has proved to be the indispensable tool for an almost histological analysis of the eye. Indeed, by using a light beam scanning the retina (or other structures), the OCT allows to establish an image according to different degrees of reflectivities corresponding to the different cell layers with a resolution currently around 5 to 10 μm. In addition, this technique has almost all the advantages: non-invasive, fast, reliable, reproducible and delegable. This explains its tremendous development and its generalization to a specialized but also general ophthalmological activity. France is probably the world's most equipped country in OCT, which makes French ophthalmologists experienced users. To get the most out of it, you need to know the technical principles and the different developments as well as the key points for carrying out and interpreting the examination. This article is the update of “Technique and interpretation of optical coherence tomography”.

El texto completo de este artículo está disponible en PDF.

Mots-clés : Tomographie en cohérence optique, Imagerie, Rétine, Macula, Dégénérescence maculaire liée à l'âge, Œdème maculaire

Keywords : Optical coherence tomography, Imaging, Retina, Macula, Age-related macular degeneration, Macular edema


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Artículo precedente Artículo precedente
  • Angiographies du fond d'œil : technique et interprétation
  • J.-L. Bacquet, S. Nghiêm-Buffet, S.Y. Cohen
| Artículo siguiente Artículo siguiente
  • Explorations électrophysiologiques sensorielles : électrorétinogramme, électro-oculogramme, potentiels évoqués visuels
  • F. Rigaudière, J.-F. Le Gargasson

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a este tratado ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.