Systemic allergy to human insulin and its rapid and long acting analogs: successful treatment by continuous subcutaneous insulin lispro infusion - 17/02/08

Doi : DM-09-2005-31-4-1262-3636-101019-200515046 

V Castéra [1],

A Dutour-Meyer [1],

MC Koeppel [2],

C Petitjean [1],

P Darmon [1]

Ver las filiaciones

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Allergie systémique à l'insuline humaine et à ses analogues de courte et longue durée d'action: efficacité de l'administration sous-cutanée continue d'insuline lispro

Depuis l'avènement de l'insuline humaine recombinante hautement purifiée, l'allergie à l'insuline est devenue un phénomène très rare, survenant chez moins de 1 % des patients. Elle peut se traduire par des manifestations immédiates ou retardées, locales ou générales, potentiellement graves. Différentes méthodes de traitement ont été proposées, d'efficacité variable, l'utilisation des analogues de l'insuline s'étant révélée bénéfique dans certaines situations. Nous rapportons le cas d'un patient de 50 ans diabétique de type 2 qui a présenté des réactions allergiques d'abord locales puis générales, allant jusqu'au choc anaphylactique à la suite de l'introduction d'une insulinothérapie avec des mélanges fixes d'analogues rapides. Les intradermo-réactions (IDR) réalisées avec l'insuline porcine, humaine et différents analogues (lispro, aspart, glargine) étaient toutes positives, tout comme les IgE spécifiques anti-insuline. Devant l'impossibilité d'obtenir une normoglycémie avec un traitement oral maximal et un régime hypocalorique, nous avons décidé de réaliser une désensibilisation par pompe sous cutanée avec l'analogue lispro, car c'est avec cette insuline qu'était observée la plus faible réaction lors des IDR. Nous avons ainsi pu induire une tolérance, grâce à des débits très faibles et augmentés très progressivement, sans bolus, sous couverture antihistaminique. Six mois plus tard, le patient ne présentait plus aucune réaction, et son équilibre glycémique était satisfaisant. Nous décrivons ainsi un premier cas d'allergie à l'insuline humaine et à tous les analogues rapides et lents disponibles. Nous montrons l'intérêt du traitement par pompe externe avec analogues pour l'induction de tolérance.

Systemic allergy to human insulin and its rapid and long acting analogs: successful treatment by continuous subcutaneous insulin lispro infusion

Since the introduction of highly purified human recombinant insulin, allergy to insulin has become a very rare clinical situation, encountered in less than 1% of patients. It results in potentially life-threatening immediate or delayed, local and general manifestations. Different treatments of unequal efficiency have been proposed, the use of insulin analogs showing benefits in certain situations. We report the case of a type 2 diabetic patient who presented local reactions and then an anaphylactic shock after the introduction of insulin analog premixes. Intra-dermal reactions performed with porcine, human and insulin analogs preparations (aspart, lispro, glargine) were all positive, as well as the specific anti-insulin IgE measurement. Because we could not achieve normoglycaemia with maximal oral treatment and low caloric diet, we decided to attempt a desensitisation by continuous subcutaneous infusion of insulin lispro, since the lowest skin reaction was obtained with this insulin. We were able to induce a tolerance, by means of very low basal rate, very slowly increased, without any boluses, and maintaining antihistamine therapy. Six months later, the patient remains free of any symptom and has achieved a quite good glycaemic control. We describe for the first time a case of allergy to human insulin and to all available rapid and long acting analogs. We show the interest of a treatment with CSII of analogs in order to induce tolerance.


Mots clés : Allergie à l'insuline , Analogues de l'insuline , Dosage des IgE , Induction de tolérance

Keywords: Allergy to insulin , Insulin analogs , IgE detection , Tolerance induction


Esquema



© 2005 Elsevier Masson SAS. Tous droits réservés.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 31 - N° 4

P. 391-400 - septembre 2005 Regresar al número
Artículo precedente Artículo precedente
  • Active stents in diabetic patients
  • G Drobinski, C Le Feuvre
| Artículo siguiente Artículo siguiente
  • Advantages to using capillary blood ?-hydroxybutyrate determination for the detection and treatment of diabetic ketosis
  • B Guerci, N Tubiana-Rufi, B Bauduceau, R Bresson, A Cuperlier, C Delcroix, D Durain, C Fermon, JP Le Floch, C Le Devehat, V Melki, L Monnier, H Mosnier-Pudar, P Taboulet, H Hanaire-Broutin

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.