Résumé

But de l’étude

Il était de comparer les résultats pressionnels à un an postopératoire avec le MicroShunt® d’InnFocus avec ou sans chirurgie de la cataracte associée, selon différents emplacements et concentrations de la MMC.

Étude

Il s’agit d’une étude rétrospective sur deux centres avec deux chirurgiens (France et République dominicaine).

Patients et méthodes

Les adultes devant bénéficier d’une chirurgie filtrante pour glaucome chronique à angle ouvert ont bénéficié d’un MicroShunt® sur un œil. L’effet de la concentration et du lieu d’application de la MMC a été étudié sur la PIO et sur la diminution du nombre de collyres anti-glaucomateux à un an.

Résultats

Quatre-vingt-sept yeux ont été étudiés avec un suivi d’un an. Vingt-trois yeux traités avec de la MMC à une concentration de 0,4mg/mL près du limbe ont eu une baisse de PIO de 55 %, passant de 23,8±5,3mmHg en préopératoire à 10,7±2,8mmHg à un an. Le nombre de molécules hypotonisantes par patient a été diminué de 85 %, passant de 2,4±0,9 à 0,3±0,8. Trente et un yeux traités avec de la MMC à une concentration de 0,2mg/mL près du limbe ont eu une baisse de PIO de 52 %, passant de 27,9±6,7mmHg en préopératoire à 13,3±3,3mmHg à un an. Le nombre de molécules hypotonisantes par patient a été diminué de 88 %, passant de 2,5±1,4 à 0,5±1,0. Trente-trois yeux traités avec de la MMC à une concentration de 0,4mg/mL loin du limbe ont eu une baisse de PIO de 38 %, passant de 25,4±7,9mmHg en préopératoire à 15,7±4,6mmHg à un an. Le nombre de molécules hypotonisantes par patient a été diminué de 72 %, passant de 2,9±1,0 à 0,8±1,3. Il n’y a pas eu de complications menaçant la fonction visuelle.

Conclusion

Le MicroShunt® d’InnFocus est une chirurgie filtrante dont l’efficacité dépend de la localisation et de la concentration de la MMC utilisée.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

To compare intraocular pressure (IOP) at one year with the InnFocus MicroShunt® with or without cataract surgery with according to placement and concentration of mitomycin C (MMC)

Design

A retrospective two-center, two-surgeon study (France and Dominican Republic).

Patients and methods

Adults with POAG requiring filtering surgery. One MicroShunt® was placed in one eye of each patient. The effect of concentration and site of application of MMC was assessed by IOP and medication reduction at one year.

Results

Eighty-seven eyes were studied with one-year follow-up. Twenty-three eyes treated with 0.4mg/mL MMC close to the limbus demonstrated a 55% reduction in IOP from 23.8±5.3 at baseline to 10.7±2.8mmHg at one year. Topical glaucoma medication/patient was reduced 85% from 2.4±0.9 to 0.3±0.8. Thirty-one eyes treated with 0.2mg/mL MMC close to the limbus demonstrated a 52% reduction in IOP from 27.9±6.7 at baseline to 13.3±3.3mmHg at one year. Topical glaucoma medication/patient was reduced 88% from 2.5±1.4 to 0.5±1.0. Thirty-three eyes treated with 0.4mg/mL MMC deep in the pocket demonstrated a 38% reduction in IOP from 25.4±7.9 at baseline to 15.7±4.6mmHg at one year. Topical glaucoma medication/patient was reduced 72% from 2.9±1.0 to 0.8±1.3. There were no sight-threatening long-term adverse events.

Conclusion

The InnFocus MicroShunt® is a filtering surgery whose efficacy is related to the location of application and concentration of MMC used.

Le texte complet de cet article est disponible en PDF.

Mots clés : Chirurgie du glaucome, Chirurgie filtrante, Chirurgie mini-invasive du glaucome, MicroShunt®

Keywords : Glaucoma surgery, Filtering surgery, Minimally invasive surgery for glaucoma, MicroShunt®


Plan


 Communication orale présentée lors du 121e Congrès de la Société française d’ophtalmologie en mai 2015.


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 38 - N° 9

P. 855-860 - novembre 2015 Retour au numéro
Article précédent Article précédent
  • Évaluation de l’efficacité de l’ECP à laser diode combinée à une chirurgie de cataracte dans le glaucome
  • S.M. Ezzouhairi
| Article suivant Article suivant
  • Les membranes épirétiniennes maculaires
  • B. Dupas, R. Tadayoni, A. Gaudric

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.