Abstract

Recent publications on patient-specific instrumentation for total knee arthroplasty have reported considerable variability in the axial positioning of the cutting guides for the femoral component. These personalized cutting guides are manufactured based on bone shape data, generated from magnetic resonance imaging (MRI) or computed tomography (CT). The goal of this study was to compare the reproducibility and accuracy of distal femoral torsion (DFT) values measured using these two imaging modalities. We hypothesized that MRI does not reproducibly and consistently measure DFT and is not as accurate as CT scan.

Methods

Anonymized radiology records from 54 patients that included MRI and CT scans of the knee were read in random order by two observers, on two separate occasions. These records were from patients being considered for a meniscal or osteochondral graft and who had their knee explored, but who had not undergone femoral or tibial surgery and were free of osteoarthritis. The DFT was estimated using the posterior condylar angle (PCA), using both its anatomical and surgical definitions. The intra- and inter-observer reproducibility of the MRI and the differences relative to CT scan measurements were analysed.

Results

The average intra-observer difference for the MRI evaluation of the anatomical PCA was 0.8±1.2°; it was 0.4±0.9° for the surgical PCA. More than 1° difference from the average was found in 8 cases (14%) using the anatomical PCA measurement and 4 cases (7.4%) when using the surgical PCA (P=0.4). The intraclass correlation coefficients (ICCs) were 0.67 (95% CI: 0.33–0.85) and 0.74 (95% CI: 0.47–0.89) for the anatomical and surgical PCA, respectively. The average inter-observer difference for the MRI evaluation of the anatomical PCA was 1.6±1.4°; it was 1.5±1.0° for the surgical PCA. More than 1° difference from the average was found in 27 cases (50%) using the anatomical PCA measurement and 22 cases (40%) when using the surgical PCA (P=0.4). The ICCs were 0.31 (95% CI: 0.14–0.65) and 0.48 (95% CI: 0.06–0.75) for the anatomical and surgical PCA, respectively. The average differences between the CT and MRI measurements were 1.4±1.1° (0.2–5°) and 1.1±0.8° (0–3.6°) for the anatomical and surgical PCA, respectively. Greater than 1° difference between CT and MRI was found in 29 records (54%) for the anatomical PCA and in 18 records (33%) for the surgical PCA (P=0.03).

Conclusion

DFT measurement on MRI is more reproducible and consistent when using the surgical PCA. MRI measurements differed by more than 1° relative to CT measurements in more than one-third of cases.

Case control study

Level III.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal femoral torsion, MRI, CT scan, Patient-specific instrumentation, Total knee arthroplasty


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 8

P. 937-940 - décembre 2015 Retour au numéro
Article précédent Article précédent
  • Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study
  • N. Tardy, A. Maqdes, P. Boisrenoult, P. Beaufils, P. Oger
| Article suivant Article suivant
  • Cruciate-sacrificing total knee arthroplasty and insert design: A radiologic study of sagittal laxity
  • B. Appy Fedida, E. Krief, E. Havet, P. Massin, P. Mertl

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.