S'abonner

0254: Updated reference levels for radiation doses to patients undergoing coronary angiography and coronary percutaneous interventions: the RAY’ACT2 study - 12/02/16

Doi : 10.1016/S1878-6480(16)30012-X 
Jean-Louis Georges ((1)), , Loic Belle ((2)), Jean-Baptiste Azowa ((2)), Franck Albert ((3)), Michel Pansieri ((4)), Jacques Monsegu ((5)), Simon Cattan ((6))
(1) CH Versailles, Le Chesnay, France 
(2) CH Annecy-Genevois, Annecy, France 
(3) CH Chartres, Chartres, Frances 
(4) CH Avignon, Avignon, France 
(5) GH Mutualiste Grenoble, Grenoble, France 
(6) CH Montfermeil Le Raincy, Montfermeil, France 

*Corresponding author:

Résumé

Purpose

The RAY’ACT project is a nationwide, multicentre survey program aimed at evaluating patient radiation protection (RP) during coronary angiography (CA) and percutaneous coronary interventions (PCI) in French non-university public hospitals, which represent>30% of the national activity for PCIs, and 60% of the emergency cases. We present the updated reference levels based on the results of the second survey conducted in 2013 (RAY’ACT2).

Methods

RP parameters from 48,547 CAs and 40,026 PCIs performed at 61 centres during 2013 and routinely registered in professional software were extracted and analysed retrospectively. Kerma-area product (KAP), fluoroscopy time (FT), number of acquired frames (Nb F) and runs (NR), and total Air Kerma at interventional reference point (KA, r) were analysed separately for CAs and PCIs (elective and ad hoc pooled). All procedures of the year were included.

Results

The table shows the medians (Q1-Q3) of the RP parameters, updated RLs based on the 75th percentiles of the values for CA and PCI (bold), and previous RLs (RAY’ACT1, 2010).

Conclusions

Between 2010 and 2013, a 20 to 30% decrease was observed in medians and Reference Levels (Q3) for main RP parameters, including KAP and total Air Kerma.


Abstract 0254 – Table: Results2013 (RAY’ACT2) 61 centres2010 (RAY’ACT1) 44 centresCAN=48,547N=31,066KAP (Gy.cm²)20.9 (11.8-35.7)27.2 (15.5-45.2)FT (min)3.3 (2.1-5.7)3.7 (2.3-6.3)Nb Frames404 (284-566)553 (388-769)KA,r (mGy)294 (164-498)421 (240-695)PCIN=40,026N=25,356KAP (Gy.cm²)45.2 (25.6-77.6)56.8 (32.8-94.6)FT (min)9.8 (6.3-15.4)10.3 (6.7-16.2)Nb Frames676 (465-960)837 (578-1193)KA,r (mGy)747 (421-1285)1052 (589-1788)

 2013 (RAY’ACT2) 61 centres 2010 (RAY’ACT1) 44 centres 
CA N=48,547 N=31,066 
KAP (Gy.cm²20.9 (11.8-35.727.2 (15.5-45.2
FT (min) 3.3 (2.1-5.73.7 (2.3-6.3
Nb Frames 404 (284-566553 (388-769
KA,r (mGy) 294 (164-498421 (240-695
PCI N=40,026 N=25,356 
KAP (Gy.cm²45.2 (25.6-77.656.8 (32.8-94.6
FT (min) 9.8 (6.3-15.410.3 (6.7-16.2
Nb Frames 676 (465-960837 (578-1193
KA,r (mGy) 747 (421-12851052 (589-1788

Le texte complet de cet article est disponible en PDF.

© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 8 - N° 1

P. 4 - janvier 2016 Retour au numéro
Article précédent Article précédent
  • 0107: Radiation exposure of the operator during coronary interventions: comparison of right radial, left radial and right femoral approach
  • Zacharenia Kallinikou, Serban Puricel, Mario Togni, Gerard Baeriswyl, Jean-Christophe Stauffer, Stephane Cook, Nick Ryckx, Francis Verdun, Jean-Jacques Goy
| Article suivant Article suivant
  • 0368: Radiation in transfemoral versus transradial access in diagnostic coronary angiography
  • Martha Habibi, Panagiotis Karyofyllis, Vassilis Voudris

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.