S'abonner

Cementless Corailtm femoral stems with laser neck etching: Long-term survival, rupture rate and risk factors in 295 stems - 13/02/16

Doi : 10.1016/j.otsr.2015.10.009 
A. Merini a, A. Viste a, b, c, d, , R. Desmarchelier a, M.-H. Fessy a, b, c, d
a Hospices civils de Lyon, centre hospitalier Lyon-Sud, service de chirurgie orthopedique et traumatologique, 165, chemin Grand-Revoyet, 69495 Pierre-Bénite cedex, France 
b Université de Lyon, 69622 Lyon, France 
c Université Claude-Bernard Lyon 1, 43, boulevard du 11-Novembre, 69100 Villeurbanne, France 
d IFSTTAR, UMRT 9406, laboratoire de biomécanique et mécanique des chocs, 25, avenue Mitterrand, 69500 Bron, France 

Corresponding author. Service de chirurgie orthopédique et traumatologique, centre hospitalier Lyon-Sud, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France. Tel.: +33 4 78 86 37 38; fax: +33 4 78 86 59 34.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Implant neck fracture involving a non-modular femoral stem is rare in primary total hip arthroplasty (THA). Occasional cases have been reported following laser etching of the Corailtm stem, but risk factors have not been precisely determined. We therefore performed a retrospective study on a series of Corailtm stems with laser neck etching, in order to: (1) determine the exact implant neck fracture rate at 10 years, and (2) identify associated risk factors.

Hypothesis

Laser etching increases the rate of implant neck fracture.

Materials and methods

Between October 2002 and December 2003, 295 THAs were consecutively performed using the Corailtm stem with laser neck etching, in 286 patients: 151 male (53%), 135 female (47%); mean age, 63 years (range, 18–89 years); mean weight, 73kg (range, 45–120kg). Stems were standard in 240 cases (81%) and lateralized in 55 (19%). The main assessment criterion was stem replacement for implant neck fracture.

Results

At a mean 10 years’ follow-up (range, 1–11 years), 11 patients were lost to follow-up (4%) and 35 had died (12%) (with stem in situ). Overall 10-year stem survival was 91% (95% CI: [87–94%]). Sixteen patients (5.4%) underwent revision surgery for implant neck fracture, 6 (2%) bone and joint infection and in 4 cases (1.3%) the stem was replaced preventively for fracture risk suspected during a revision procedure on the cup. All fractures were of the fatigue type, implicating implant neck laser etching. Mean time to fracture was 4.5 years (range, 1.4–9.8 years). Risk factors comprised: weight>80kg (P=0.002) (OR=5.7; 95% CI: 1.9–17), age<60 years (P=0.02) (OR=3.4; 95% CI: 1.2–9.6), male gender (P=0.01) (OR=14.8; 95% CI: 1.9–113) and lateralized stem (P<0.001) (OR=6.5, 95% CI: 2.3–18).

Conclusion

The present 5.4% fracture rate was higher than in registry data (<1%). Fracture mechanisms involved excessive stress in an area under tension, leading to fatigue fracture. Male gender, high weight and young age were risk factors, as in the literature for fatigue fracture. Location and depth of laser etching induced fatigue fracture. The study demonstrated that laser etching creates an area of weakness in the implant neck and should therefore be eschewed in this part of the femoral stem.

Level of evidence

IV, retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Stem neck fracture, Laser etching, Total hip arthroplasty, Corailtm stem


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 1

P. 71-76 - février 2016 Retour au numéro
Article précédent Article précédent
  • Hidden blood loss in anterior lumbar interbody fusion (ALIF) surgery
  • H. Ju, R.A. Hart
| Article suivant Article suivant
  • Incidence and characteristics of proximal femoral fractures in an Afro-Caribbean population
  • J.-L. Rouvillain, F. De Cazes, R. Banydeen, K. Rome, P. Numéric, M. De Bandt, C. Derancourt

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.