Repositionnement par le système ExacTrac® pour l’irradiation sans cadre invasif de métastases cérébrales en conditions stéréotaxiques : étude descriptive de cinq centres français - 28/01/17

Doi : 10.1016/j.canrad.2016.04.007 
T. Ohnleiter a, M.-A. Mahé b, J. Biau c, D. Wdowczyk d, J.-B. Clavier a, D. Antoni a, e, G. Noël a, , e
a Département de radiothérapie, centre de lutte contre le cancer Paul-Strauss, 3, rue de la Porte-de-l’Hôpital, 67065 Strasbourg, France 
b Département de radiothérapie, institut de cancérologie de l’Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint-Herblain cedex, France 
c Département de radiothérapie, centre Jean-Perrin, 58, rue Montalembert, 63000 Clermont-Ferrand, France 
d Département de radiothérapie, institut du cancer Courlancy, 38, rue de Courlancy, 51100 Reims, France 
e Laboratoire EA 3430, Fédération de médecine translationnelle de Strasbourg (FMTS), université de Strasbourg, 67000 Strasbourg, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 4
Vidéos 0
Autres 0

Résumé

Objectif de l’étude

Analyser les protocoles de repositionnement de différents centres français utilisant le système ExacTrac® associé à un accélérateur linéaire dédié de type Novalis®, pour le traitement en conditions stéréotaxiques des métastases cérébrales.

Matériels et méthodes

Un questionnaire comprenant trois questions sur la prescription de la radiothérapie et vingt-et-une questions sur les modalités d’utilisation du système ExacTrac® a été adressé aux responsables médicaux de neuf centres français disposant d’un accélérateur dédié de type Novalis®. Cinq centres ont accepté de participer à l’étude.

Résultats

Tous les centres réalisaient une vérification de positionnement avant chaque arc de traitement, avec des tolérances de décalage résiduel de 0,5 à 0,7mm pour les translations et de 0,5 à 1° pour les rotations. Tous sauf un réalisaient également des images planaires orthogonales d’incidences classiques, table de traitement à 0°, afin d’aider les soignants à vérifier le bon positionnement de l’isocentre. Les doses prescrites étaient de 20Gy en une séance, 30Gy ou 33Gy en trois fractions ou 34Gy en quatre fractions, le choix se faisant essentiellement en fonction de la taille de la lésion. Enfin, toutes les images de repositionnement étaient validées médicalement au poste de traitement avant de débuter l’irradiation.

Conclusions

Les pratiques des différents centres concernant les protocoles de recalages étaient globalement homogènes, en accord avec les données de la littérature concernant la précision du système ExacTrac® ; il en était de même pour les fractionnements thérapeutiques proposés. La validation médicale systématique au poste de traitement pourrait être remise en question du fait du temps d’attente entre l’appel du médecin et la validation, et surtout de son utilité même car les corrections médicales sont rares à inexistantes.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

This study aimed to analyse the positioning protocols with the ExacTrac® system, associated with a dedicated linear accelerator such as Novalis®, for stereotactic treatment of brain metastases in several French centres.

Materials and methods

A survey, including three questions about the prescription of irradiation and twenty-one questions about how the ExacTrac® system is used, was sent to nine French centres owning a dedicated Novalis® accelerator. Five centres have accepted to participate in the study.

Results

All centres checked the positioning before each treatment's bow, with residual mismatch tolerances of 0.5 to 0.7mm for the translations and 0.5 to 1° for the rotations. All centres except one also realised orthogonal planar images of classic incidences to help operators ensure proper isocentre positioning. Prescribed doses were 20Gy in one fraction, 30Gy and 33Gy in three fractions or 34Gy in four fractions, mainly depending on the size of the lesion. Finally, a physician validated the images at the treatment station before starting the irradiation.

Conclusions

The practices of the different centres concerning the positioning protocols were rather homogeneous, in agreement with the literature data on ExacTrac® system's accuracy, as well as proposed fractionations. The systematic medical validation at the treatment station may, however, be questioned because of the waiting time between the doctor's call and validation itself and because of its usefulness; indeed, corrections by the radiation oncologist are very rare and in some centres, non-existent.

Le texte complet de cet article est disponible en PDF.

Mots clés : Radiothérapie en conditions stéréotaxique, Traitement sans cadre, ExacTrac®, Novalis®, Métastase cérébrale

Keywords : Stereotactic irradiation, Brain metastasis, Frameless, ExacTrac®, Novalis®


Plan


© 2016  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 8

P. 768-775 - décembre 2016 Retour au numéro
Article précédent Article précédent
  • Evaluation of patients’ engagement in radiation therapy safety
  • A. Pernet, V. Mollo, J.-E. Bibault, P. Giraud
| Article suivant Article suivant
  • Feasibility evaluation of prone breast irradiation with the Sagittilt© system including residual-intrafractional error assessment
  • F. Lakosi, A. Gulyban, S. Ben-Mustapha Simoni, P. Viet Nguyen, P. Berkovic, M. Noël, N. Gourmet, P. Coucke

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.