S'abonner

Preoperative grading of supratentorial gliomas using high or standard b-value diffusion-weighted MR imaging at 3T - 04/03/17

Doi : 10.1016/j.diii.2016.11.005 
M.M. Cihangiroglu a, , E. Ozturk-Isik b, Z. Firat c, O. Kilickesmez d, A.M. Ulug b, e, U. Ture f
a Bahçeşehir University, Department of Radiology, Medical Park Göztepe Hospital, Merdivenköy, Kadıköy, 34000 İstanbul, Turkey 
b Institute of Biomedical Engineering, Boğaziçi University, Istanbul, Turkey 
c Department of Radiology, Yeditepe University Hospital, Istanbul, Turkey 
d Department of Radiology, Istanbul Education and Research Hospital, Istanbul, Turkey 
e CorTechs Labs, Inc, San Diego, CA, USA 
f Department of Neurosurgery, Yeditepe University Hospital, Istanbul, Turkey 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

The goal of this study was to compare diffusion-weighted magnetic resonance imaging (DW-MRI) using high b-value (b=3000s/mm2) to DW-MRI using standard b-value (b=1000s/mm2) in the preoperative grading of supratentorial gliomas.

Materials and methods

Fifty-three patients with glioma had brain DW-MRI at 3T using two different b-values (b=1000s/mm2 and b=3000s/mm2). There were 35 men and 18 women with a mean age of 40.5±17.1 years (range: 18–79 years). Mean, minimum, maximum, and range of apparent diffusion coefficient (ADC) values for solid tumor ROIs (ADCmean, ADCmin, ADCmax, and ADCdiff), and the normalized ADC (ADCratio) were calculated. A Kruskal–Wallis statistic with Bonferroni correction for multiple comparisons was applied to detect significant ADC parameter differences between tumor grades by including or excluding 19 patients with an oligodendroglioma. Receiver operating characteristic curve analysis was conducted to define appropriate cutoff values for grading gliomas.

Results

No differences in ADC derived parameters were found between grade II and grade III gliomas. Mean ADC values using standard b-value were 1.17±0.27×10−3mm2/s [range: 0.63–1.61], 1.05±0.22×10−3mm2/s [range: 0.73–1.33], and 0.86±0.23×10−3mm2/s [range: 0.52–1.46] for grades II, III and IV gliomas, respectively. Using high b-value, mean ADC values were 0.89±0.24×10−3mm2/s [range: 0.42–1.25], 0.82±0.20×10−3mm2/s [range: 0.56–1.10], and 0.59±0.17×10−3mm2/s [range: 0.40–1.01] for grades II, III and IV gliomas, respectively. ADCmean, ADCratio, ADCmax, and ADCmin were different between grade II and grade IV gliomas at both standard and high b-values. Differences in ADCmean, ADCmax, and ADCdiff were found between grade III and grade IV only using high b-value.

Conclusion

ADC parameters derived from DW-MRI using a high b-value allows a better differential diagnosis of gliomas, especially for differentiating grades III and IV, than those derived from DW-MRI using a standard b-value.

Le texte complet de cet article est disponible en PDF.

Keywords : Glioma, Diffusion-weighted MR imaging, High b-value, Tumor grading, Normalized apparent diffusion coefficient (ADC)


Plan


© 2016  Éditions françaises de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 3

P. 261-268 - mars 2017 Retour au numéro
Article précédent Article précédent
  • Evaluation of tumor response to intra-arterial chemoembolization of hepatocellular carcinoma: Comparison of contrast-enhanced ultrasound with multiphase computed tomography
  • S.B. Paul, E. Dhamija, S.R. Gamanagatti, V. Sreenivas, D.P. Yadav, S. Jain, S.K. Acharya
| Article suivant Article suivant
  • CT and MR imaging findings of teratoma of the Eustachian tube
  • C. Rondenet, S. Boudjemaa, C. Sileo, E.-N. Garabedian, H. Ducou le Pointe, E. Blondiaux

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.