Délégation partielle du contrôle quotidien de position de la prostate par tomographie conique aux manipulateurs en électroradiologie médicale - 08/03/17

Doi : 10.1016/j.canrad.2016.07.104 
C. Benhaïm a, G. Loos a, J.L. Achard a, L. Berger b, C. Caillé a, T. Frédéric-Moreau a, J. Biau a, M. Lapeyre a,
a Département de radiothérapie, centre Jean-Perrin, 58, rue Montalembert, BP 392, 63011 Clermont-Ferrand cedex 1, France 
b Département de physique médicale, centre Jean-Perrin, 58, rue Montalembert, BP 392, 63011 Clermont-Ferrand cedex 1, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 4
Vidéos 0
Autres 0

Résumé

Objectif de l’étude

La radiothérapie avec modulation d’intensité des cancers de prostate implique des contrôles quotidiens du positionnement de la prostate, possible avec la tomographie conique (cone beam computed tomography, CBCT). Il permet une augmentation de la précision mais induit une augmentation du temps médical dédié à ces contrôles. L’objectif de l’étude a été d’évaluer la possibilité de délégation de cette tâche aux manipulateurs en électroradiologie médicale en comparant leurs recalages à ceux des médecins.

Patients et méthodes

Les dossiers de cinq patients consécutifs atteints par un cancer de prostate traité par irradiation de 76Gy ont été analysés. Tous ont eu une tomographie conique chaque jour pour le contrôle de position. Les mouvements de la prostate par rapport au cadre osseux, les variations de position de la prostate mesurées par les manipulateurs en électroradiologie médicale et les médecins et le temps médical nécessaire pour analyser l’imagerie (remplissage du rectum et de la vessie et effectuer un recalage) ont été mesurés.

Résultats

Cent-soixante-seize tomographies coniques ont été analysées, soit 980 mesures dans les trois axes. Les mouvements de la prostate par rapport au cadre osseux étaient respectivement supérieurs ou égaux à 5mm dans 19 %, 7 % et 3 % dans les axes antéropostérieur, supéro-inférieur et droite–gauche. Les variations des recalages entre les manipulateurs en électroradiologie médicale et les médecins étaient dans 95 % des cas inférieures ou égales à 4mm dans les axes antéropostérieur et supéro-inférieur, et 3mm dans l’axe droite–gauche. Le temps de mobilisation médicale était en moyenne de 8min 40 [4 à 22min].

Conclusion

Le recalage quotidien sur la prostate utilisant la tomographie conique peut être délégué aux manipulateurs en électroradiologie médicale avec une concordance acceptable de moins de 4mm pour 95 % des mesures. Une formation initiale et continue permet d’assurer la sécurité des traitements.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

Intensity modulated radiotherapy for prostate cancer involves daily monitoring of the positioning of the prostate, possible with cone beam CT (CBCT). It allows increased accuracy compared to readjustments but induces an increase in the time dedicated to these medical checks. The aim of the study was to evaluate the possibility of delegation of this task to the radiation therapists by comparing their readjustments to the doctors.

Patients and methods

Five consecutive patients treated with radiation for prostate cancer (76Gy) were analysed. All had a daily CBCT for position control. The movements of the prostate relative to the bony part, the positional variations of the prostate measured by the radiation therapists and the doctors and medical time required to analyse imagery (filling of the rectum and bladder and perform a recalibration) were measured.

Results

One hundred seventy-six CBCT were analysed or 980 steps in the three axes. The movements of the prostate relative to bony part were respectively at least 5mm in 19%, 7% and 3% in the anterior–posterior, upper–lower and right–left axes. Changes readjustments between radiation therapists and doctors were in 95% of cases at the most 4mm in the anterior–posterior and upper–lower axis, and 3mm in the left–right axis. The time for medical use of the CBCT averaged 8min 40 [4 to 22min].

Conclusion

The daily readjustment on the prostate using CBCT may be delegated to radiation therapists with acceptable concordance of less than 4mm for 95% of measurements. An initial and ongoing training will ensure treatment safety.

Le texte complet de cet article est disponible en PDF.

Mots clés : Délégation, Tomographie conique, Cancer de prostate, IGRT

Keywords : Delegation, Cone beam CT, Prostate cancer, IGRT


Plan


© 2017  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 21 - N° 1

P. 28-33 - février 2017 Retour au numéro
Article précédent Article précédent
  • Implementation of intensity-modulated radiotherapy for head and neck cancers in routine practice
  • C. Bednarek, T.V.F. Nguyen, M. Puyraveau, É. Bonnet, N. Lescut, C. Azélie, J. Miny, O. Mauvais, T. Maurina, F. Tochet, J.-F. Bosset, J. Thariat, X.S. Sun
| Article suivant Article suivant
  • Target volume delineation for radical radiotherapy of early oesophageal carcinoma in elderly patients
  • J. Su, S. Zhu, Z. Liu, Y. Zhao, C. Song

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.