S'abonner

Successful outcome with minimally invasive plate osteosynthesis for periprosthetic tibial fracture after total knee arthroplasty - 30/03/17

Doi : 10.1016/j.otsr.2016.10.007 
H.-J. Kim a, K.-C. Park b, J.-W. Kim a, C.-W. Oh a, , H.-S. Kyung a, J.-K. Oh c, K.-H. Park a, S.-D. Yoon a
a Department of Orthopedic Surgery, Kyungpook National University Hospital, 700-721 Daegu, Republic of Korea 
b Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea 
c Department of Orthopedic Surgery, Korea University Guro Hospital, Seoul, Republic of Korea 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

The incidence of periprosthetic fractures after total knee arthroplasty (TKA) is increasing, and treatment is becoming more necessary. In periprosthetic tibial fractures, the stem of the tibial component largely occupies the medullary canal of the proximal tibia, which limits the selection of implants. The purpose of this study was to evaluate the effectiveness of the minimally invasive plate osteosynthesis (MIPO) technique with locking plates for periprosthetic tibial fractures after TKA.

Materials and methods

Sixteen patients with periprosthetic tibial fracture after TKA were included. There were 6 type II and 10 type III fractures according to the Felix classification. Ten patients had fractures in the proximal metaphysis, and 6 in the diaphysis. MIPO using locking plates was performed on the medial side in 4 cases, the lateral side in 2 cases, and both in 10 cases. Radiographic results included time to union, alignment, and malunion. Clinical results included range of motion (ROM), functional activity data, Knee Society scores, and complications.

Results

Fourteen of 16 fractures achieved union at 17.1 weeks (range, 14–24) postoperatively. There were 2 failures that required a secondary procedure. Except one for 1 case with varus malunion, all had acceptable alignment. Mean ROM at the final follow-up was 108.8° (range, 15–135°), and 15 patients recovered pre-injury knee joint activity. Mean knee and function scores were 88.9 (range, 77–100) and 83.3 (range, 60–100), respectively. Knees with fewer than 8 cortices giving purchase to screws in the proximal segment showed higher failure rates (P=0.025).

Discussion

MIPO with locking plates can achieve satisfactory results for periprosthetic tibial fractures after TKA. Rigid fixation of the proximal segment may be necessary for successful outcome.

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee arthroplasty, Periprosthetic tibial fracture, Minimally invasive plate osteosynthesis, Locking plate


Plan


© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 2

P. 263-268 - avril 2017 Retour au numéro
Article précédent Article précédent
  • Periprosthetic fractures of the distal femur after total knee arthroplasty : Plate versus nail fixation
  • S.S. Wallace, D. Bechtold, A. Sassoon
| Article suivant Article suivant
  • Distal femoral hemiepiphysiodesis using screw and non-absorbable filament for the treatment of idiopathic genu valgum. Preliminary results of 12 knees
  • G. Martínez, S. Drago, C. Avilés, A. Ibañez, F. Hodgson, C. Ramírez

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.