Nouveau procédé pour fendre le cristallin à l'aide de micromanipulateurs à bords mousses au cours de la phakoémulsification - 08/03/08
F. Deschatres
A new procedure for fragmenting the lens with soft-edge micromanipulation during phacoemulsification |
During phacoemulsification:
Presentation of a new method of manual nucleofracture performed with the use of small-volume and soft-edge micromanipulators.
This method presents several advantages:
- The procedure is rapid and easy to learn
- It allows true fragmentation of the lens in to many small pieces for easy and fast emulsification
- It avoids the most serious complication of posterior capsular rupture
During the last three years 1200cataract operations have been performed without capsulor rupture and without durable endothelial damage.
Nouveau procédé pour fendre le cristallin à l'aide de micromanipulateurs à bords mousses au cours de la phakoémulsification |
Au cours de la phakoémulsification.
Présentation d'une nouvelle méthode de nucléofracture manuelle simplifiée à l'aide de deux micromanipulateurs de petit volume et à bords mousses.
Cette méthode présente des avantages:
- de permettre une fragmentation du cristallin rapide ;
- d'apprentissage facile ;
- de permettre une véritable dislocation du cristallin donc une émulsification plus rapide ;
- et surtout d'éviter la complication importante qu'est la rupture de la capsule postérieure.
1200cataractes ont ainsi été effectuées sans atteinte capsulaire et sans atteinte endothéliale durable.