S'abonner

Tear lipid layer thickness and ocular comfort with a novel device in dry eye patients with or without Sjogren’s syndrome - 08/03/08

Doi : JFO-04-2007-30-4-0181-5512-101019-200702136 

A. Spiteri [1],

M. Mitra [1],

G. Menon [1],

A. Casini [2],

D. Adams [2],

C. Ricketts [4],

P. Hickling [4],

E.T. Fuller [5],

J.R. Fuller [1]

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Épaisseur de la couche lipidique et confort oculaire après utilisation d’un nouveau dispositif médical en cas de syndrome sec dû ou non à un Syndrome de Gougerot-Sjögren (en anglais)

But de l’étude : Mesurer les changements de l’épaisseur de la couche lipidique (ECL) du film lacrymal et des symptômes de patients présentant une symptomatologie d’œil sec avec ou sans syndrome de Gougerot-Sjögren, après l’utilisation d’un nouveau dispositif médical. Le dispositif vise à faciliter la libération de meibum dans le film lacrymal grâce à la libération d’une chaleur latente aux paupières.

Design de l’étude : Deux études prospectives, comparatives, randomisées, en simple insu (investigateur masqué) après une application unique.

Méthodes : Deux études ont été menées dans un Hôpital Universitaire dans le sud-ouest de l’Angleterre. La première étude a concerné 24 patients avec des symptômes d’œil sec sans syndrome de Gougerot-Sjögren (Étude PDE) et la deuxième étude incluait 31 patients avec des symptômes d’œil sec consécutif à un syndrome de Gougerot- Sjögren (Étude SS). L’étude PDE était randomisée en deux groupes. Le Groupe I (12 patients) a reçu un traitement pendant 10 minutes avec le dispositif activé et le Groupe II (12 patients) n’a reçu aucun traitement. De façon identique, lors de l’étude SS, les patients étaient randomisés en deux groupes : groupe I (12 patients) et groupe II (14 patients). L’épaisseur de la couche lipidique et les modifications subjectives du confort oculaire ont été mesurées pour chaque sujet avant l’application, puis après 5 et 30 minutes d’utilisation.

Résultats : Dans l’étude PDE, les patients traités ont présenté une augmentation bilatérale de l’épaisseur de la couche lipidique à 5 minutes (1,2 grade pour l’œil droit — p ≪ 0,0005 — ; de 1,0 grade pour l’œil gauche — p ≪ 0,0005 —, test de Mann-Whitney) et à 30 minutes (0,7 grade pour l’œil droit — p ≪ 0,005 — ; 0,6 grade pour l’œil gauche — p ≪ 0,005 —). La moyenne des scores des symptômes s’est améliorée dans le groupe des sujets traités par rapport au groupe contrôle à 5 minutes (+ 2,0 pour le groupe des sujets traités et + 0,2 pour le groupe contrôle, — p ≪ 0,05 —) et à 30 minutes (+ 2,8 pour le groupe de sujets traités et + 0,4 pour le groupe contrôle — p ≪ 0,015 —). Dans l’étude SS, les patients traités ont présenté une augmentation bilatérale de l’épaisseur du film lacrymal à 2 minutes (0,5 grade pour l’œil droit, — p ≪ 0,009 — ; 0,5 grade pour l’œil gauche, — p ≪ 0,005 — ; test bilatéral de Monte-Carlo), à 30 minutes (0,5 grade pour l’œil droit, — p ≪ 0,007— ; 0,5 grade pour l’œil gauche, — p ≪ 0,002 —) et à 60 min (0,3 grade pour l’œil droit, — p ≪ 0,1 — ; 0,3 grade pour l’œil gauche, — p ≪ 0,05 —). Aucun des patients dans le groupe contrôle n’a présenté de changement, et ceci quel que soit le temps d’évaluation. La moyenne des scores des symptômes s’est améliorée dans le groupe des sujets traités par rapport au groupe contrôle à 5 minutes (+ 0,8 pour le groupe des sujets traités et + 0,1 pour le groupe contrôle — p ≪ 0,1 —) ; à 30 minutes (+ 1,3 pour le groupe de sujets traités et + 0,1 pour le groupe contrôle, — p ≪ 0,03 —) ; à 60 min (+ 1,5 pour le groupe de sujets traités et + 0,1 pour le groupe contrôle — p ≪ 0,02 —).

Conclusion : Le traitement des glandes de Meibomius par ce nouvel appareil améliore l’épaisseur de la couche lipidique chez les patients présentant une sécheresse oculaire avec ou sans syndrome de Gougerot-Sjögren.

Tear lipid layer thickness and ocular comfort with a novel device in dry eye patients with and without Sjögren’s syndrome

Background: To measure changes in tear-film lipid-layer thickness (LLT) and symptoms in patients with dry eye symptoms with and without Sjögren’s syndrome after using a novel device. The device is designed to promote release of meibomian sebum into the tear film by delivering latent heat to the eyelids.

Study design: Two prospective, controlled, randomised, observer-masked, single-intervention studies.

Methods: Two independent studies were conducted in a major university hospital in the South West of England. The first study involved 24 patients with dry eye symptoms without Sjögren’s [the PDE study] and the second study involved 31 patients with dry eye symptoms and Sjögren’s syndrome (the SS study). The PDE study was randomised into two groups. Group I (12 patients) underwent 10 min of treatment with the activated device and Group II (12 patients) had no treatment. The SS study was similarly randomised into Group I (17 patients) and Group II (14 patients). The LLT and subjective alterations in ocular comfort of each subject were assessed prior and immediately after 5 and 30 min subsequent to the 10-min period. In the SS study, a further assessment was carried out at 60 min.

Results: In the PDE study, treated patients exhibited a bilateral increase of LLT at 5 min (right eyes, 1.2 levels, p≪0.0005; left eyes, 1.0 levels, p≪0.0005, Mann-Whitney) and at 30 min (right eyes, 0.7 levels, p≪0.005; left eyes, 0.6 levels, p≪0.005). Mean symptom scores improved in the treated group compared with the control group at 5 min (treatment group, +2.0; control group, +0.2; p≪0.05) and 30 min (treatment group, +2.8; control group, +0.4; p≪0.015). In the SS study, treated patients exhibited a bilateral increase of LLT, 5 min (right eyes, 0.5 levels, p≪0.009; left eyes, 0.5 levels, p≪0.005, Monte Carlo 2-tailed), 30 min (right eyes, 0.5 levels, p≪0.007; left eyes 0.5 levels, p≪0.002) and 60 min (right eyes, 0.3 levels, p≪0.1; left eyes, 0.3 levels, p≪0.05). There was no change in any of the control patients in any of the assessments. With regard to symptom scores, the mean change at 5 min measured +0.8 in the treatment group and remained relatively unchanged at +0.1 in the control group (p≪0.1). At 30 min, this change measured +1.3 in the treatment group and +0.1 in the control group (p≪0.03) and at 60 min, the change measured +1.5 in the treatment group and remained at +0.1 in the control group (p≪0.02).

Conclusion: Meibomian therapy with this novel device increases LLT and ocular comfort in patients with dry eye symptoms with and without Sjögren’s syndrome


Mots clés : Sébum , glandes de Meibomius , film lacrymal , épaisseur de la couche lipidique , chaleur latente , syndrome de Gougerot-Sjögren

Keywords: Meibomian sebum , lipid layer thickness , latent heat , dry eye , Sjögren’s syndrome


Plan



© 2007 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 4

P. 357-364 - avril 2007 Retour au numéro
Article précédent Article précédent
  • Apport de la microscopie confocale in vivo et de la tomographie en cohérence optique de chambre antérieure pour l’étude des pathologies endothéliales cornéennes
  • N. Fayol, A. Labbé, S. Dupont-Monod, B. Dupas, C. Baudouin
| Article suivant Article suivant
  • Étude épidémiologique de la rétinopathie du prématuré : les facteurs de risque au CHU de Tours
  • E. Lala-Gitteau, S. Majzoub, E. Saliba, P.-J. Pisella

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.