S'abonner

Comparison of objective optical quality measured by double-pass aberrometry in patients with moderate dry eye: Normal saline vs. artificial tears: A pilot study - 04/02/18

Doi : 10.1016/j.jfo.2017.12.001 
G. Vandermeer a, , Y. Chamy a, P.-J. Pisella a, b
a Ophtalmology department, hôpital Bretonneau, CHRU Bretonneau, 2, boulevard Tonnellé, 37000 Tours, France 
b Université François Rabelais, 37000 Tours, France 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Sunday 04 February 2018
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between “normal saline” and “OF” eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the “OF” eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, P<0.05), the average slope of OSI (0.04 versus 0.01, P<0.05) and the number of blinks (4.2 versus 2.8, P<0.05). Among the patients, 65% preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline.

Le texte complet de cet article est disponible en PDF.

Keywords : Dry eye, Tear film, Quality of vision, Double-pass aberrometry, Artificial tears


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.