S'abonner

Clinical and radiological outcomes of a cohort of 9 patients with anatomical fractures of the cuboid treated by locking plate fixation - 31/03/18

Doi : 10.1016/j.otsr.2017.12.012 
L. Rony , P. de Sainte Hermine, V. Steiger, F. Ferchaud, P. Cronier
 Department of Orthopedic Surgery, CHU Angers, 4, rue Larrey, 49000 Angers, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Cuboid fractures are very rare. Hence, their treatment has not been standardized. Advances in imaging techniques, particularly three-dimensional computed tomography (3D CT), and the introduction of cuboid-specific plates has improved the care of these injuries. The aim of this study was to determine the radiological and clinical outcomes of anatomical reconstruction of comminuted cuboid fractures with a locking plate.

Hypothesis

Fixation of comminuted cuboid fractures with a cuboid-specific locking plate leads to stable anatomical reduction and good functional outcomes.

Material and methods

This was a retrospective study of 9 consecutive cases of comminuted cuboid fracture treated at a single hospital between January 2009 and December 2015. A 3D CT scan was performed preoperatively with subtraction of the posterior tarsal bone to allow the articular facets to be viewed and analyzed. Fracture fixation was done with a Locking Cuboid Plate (DePuy Synthes™). Associated lesions in the foot were treated during the same procedure. The patients were reviewed by an independent observer who performed a clinical examination, and determined the AOFAS and Maryland Foot Score. The success of the reconstruction was determined by comparing the parameters on weight-bearing X-rays views between the fixed and non-operated cuboid.

Results

The mean follow-up was 4.1 years (range 1–6). The Maryland Foot Score was 93.1 [86–100] and the AOFAS was 91.9 [82–100]. The reconstruction was anatomical and long lasting in all 9 cases. There was no foot misalignment in the frontal plane, based on the radiographs (hindfoot axis 5.5° [0–9]). The mean Djian-Annonier angle was 123.9° [108–130].

Conclusion

Cuboid fractures can be treated effectively through appropriate imaging and with a cuboid-specific locking plate as evidenced by very good midterm clinical and radiological outcomes in this study.

Level of evidence

IV Retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Cuboid fracture, Locking plate, 3D CT reconstruction


Plan


© 2018  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 2

P. 245-249 - avril 2018 Retour au numéro
Article précédent Article précédent
  • Sinus tarsi approach (STA) versus extensile lateral approach (ELA) for treatment of closed displaced intra-articular calcaneal fractures (DIACF): A meta-analysis
  • L. Bai, Y.-L. Hou, G.-H. Lin, X. Zhang, G.-Q. Liu, B. Yu
| Article suivant Article suivant
  • Mechanoreceptors distribution in the human medial collateral ligament of the elbow
  • E. Kholinne, H.-J. Lee, G.-Y. Kim, M.F. Deslivia, A. Adikrishna, Z. Bin, S.-J. Lee, I.-J. Rhyu, S.-J. Lim, H.-P. Hong, I.-H. Jeon

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.